Determination of Hg2+ on poly(vinylferrocenium) (PVF+)-modified platinum electrode

被引:21
作者
Celebi, Mutlu Soenmez [1 ]
Ozyoruk, Haluk [1 ]
Yildiz, Attila [1 ]
Abaci, Serdar [1 ]
机构
[1] Hacettepe Univ, Fac Sci, Dept Chem, TR-06532 Ankara, Turkey
关键词
Mercury determination; PVF+; Anodic stripping; Complexation; Interference; Aqueous solution; STRIPPING VOLTAMMETRIC DETERMINATION; TRACE MERCURY; GOLD; PRECONCENTRATION; FILM; SENSORS; MEDIA;
D O I
10.1016/j.talanta.2008.11.028
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
A new surface based on poly(vinylferrocenium) (PVF+)-modified platinum electrode was developed for determination of Hg2+ ions in aqueous solutions. The polymer was electrodeposited on platinum electrode by constant potential electrolysis as PVF+ClO4- Cl- ions were then attached to the polymer matrix by anion exchange and the modified electrode was dipped into Hg2+ solution. Hg2+ was preconcentrated at the polymer matrix by adsorption and also complexation reaction with Cl-. Detection of Hg2+ was carried out by differential pulse anodic stripping voltammetry (DPASV) after reduction of Hg2+. Mercury ions as low as 5 x 10(-10) M could be detected with the prepared electrode and the relative standard deviation was calculated as 6.35% at 1 x 10(-6) M concentration (n = 6). interferences of Ag+, Pb2+ and Fe3+ ions were also studied at two different concentration ratios with respect to Hg2+. The developed electrode was applied to the determination of Hg2+ in water samples. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:405 / 409
页数:5
相关论文
共 21 条
[1]
ASO C, 1969, MAKROMOLEKUL CHEM, V124, P232
[2]
BARBAROSA AC, 1997, ECOL TRACE ELEMENT R, V60, P153
[3]
Self-assembled monolayers of 2-mercaptobenzimidazole on gold: stripping voltammetric determination of Hg(II) [J].
Berchmans, S ;
Arivukkodi, S ;
Yegnaraman, V .
ELECTROCHEMISTRY COMMUNICATIONS, 2000, 2 (04) :226-229
[4]
Application of new sol-gel electrochemical sensors to the determination of trace mercury [J].
Cabello-Carramolino, G. ;
Petit-Dominguez, M. D. .
ANALYTICA CHIMICA ACTA, 2008, 614 (01) :103-111
[5]
Stripping voltammetric determination of mercury at modified solid electrodes - Determination of mercury traces using PDC/Au(III) modified electrodes [J].
Faller, C ;
Stozhko, NY ;
Henze, G ;
Brainina, KZ .
ANALYTICA CHIMICA ACTA, 1999, 396 (2-3) :195-202
[6]
Parameters affecting the determination of mercury by anodic stripping voltammetry using a gold electrode [J].
Giacomino, Agnese ;
Abollino, Omella ;
Malandrino, Mery ;
Mentasti, Edoardo .
TALANTA, 2008, 75 (01) :266-273
[7]
GULCE H, 1993, ELECTROANAL, V7, P178
[8]
Preconcentration and voltammetry of mercury on a functionalized sol-gel thin film modified glassy carbon electrode [J].
Guo, YZ ;
Guadalupe, AR .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (1-2) :175-181
[9]
Determination of total mercury in seafood by cold vapor-atomic absorption spectroscopy (CVAAS) after microwave decomposition [J].
Hight, SC ;
Cheng, J .
FOOD CHEMISTRY, 2005, 91 (03) :557-570
[10]
Selective gold-nanoparticle-based "turn-on" fluorescent sensors for detection of mercury(II) in aqueous solution [J].
Huang, Chih-Ching ;
Chang, Huan-Tsung .
ANALYTICAL CHEMISTRY, 2006, 78 (24) :8332-8338