Stripping voltammetric determination of mercury at modified solid electrodes - Determination of mercury traces using PDC/Au(III) modified electrodes

被引:70
作者
Faller, C [1 ]
Stozhko, NY
Henze, G
Brainina, KZ
机构
[1] Tech Univ Clausthal, Inst Inorgan & Analyt Chem, D-38670 Clausthal Zellerfeld, Germany
[2] Urals State Econ Univ, Ekaterinburg 620219, Russia
关键词
modified electrodes; mercury determination; stripping voltammetry;
D O I
10.1016/S0003-2670(99)00434-1
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
The paper describes the determination of mercury (II) by anodic stripping voltammetry (ASV) using modified disposable thick film graphite electrodes (MDTFGEs). The optimized conditions, interferences, and analytical applications of mercury determination using thick film electrodes modified with a gold (III)/pyrrolidinedithiocarbamate (PDC) complex are reported. The linear range for mercury determination using,these electrodes lies between 0 and 50 mu g/l, depending upon the accumulation time. The detection limit was calculated as 5 ng/l (3 sigma)for an accumulation time of 300 s. It is shown why these electrodes can be applied to the direct determination of mercury (II) without special sample treatment for samples containing:a not too large surplus of surfactants. The method is applicable to the trace analysis of mercury(II) in different water samples and sulfuric acid. (C)1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:195 / 202
页数:8
相关论文
共 16 条
[1]
Determination of methylmercury in natural water samples by steam distillation and gas chromatography atomic fluorescence spectrometry [J].
Bowles, KC ;
Apte, SC .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :395-399
[2]
VOLTAMMETRIC DETERMINATION OF TRACE AMOUNTS OF MERCURY WITH A CARBON PASTE ELECTRODE MODIFIED WITH AN ANION-EXCHANGER [J].
CAI, X ;
KALCHER, K ;
DIEWALD, W ;
NEUHOLD, C ;
MAGEE, RJ .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (01) :25-31
[3]
Flow injection determination of mercury with preconcentration by amalgamation on a gold-platinum gauze by inductively coupled plasma mass spectrometry [J].
Debrah, E ;
Denoyer, ER .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (02) :127-132
[4]
DETERMINATION OF MERCURY(II) USING A MODIFIED ELECTRODE WITH ZEOLITE [J].
HERNANDEZ, P ;
ALDA, E ;
HERNANDEZ, L .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 327 (07) :676-678
[5]
KOLB M, 1996, J ANAL CHEM+, V344, P25
[6]
Sensitive and selective determination of mercury by differential pulse stripping voltammetry after accumulation of mercury vapour on a gold plated graphite electrode [J].
Korolczuk, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (04) :389-391
[7]
*METROHM, 2591D
[8]
*METROHM, 964E
[9]
HG(II) VOLTAMMETRY ON A 1,5-DIPHENYLCARBAZIDE CONTAINING CARBON PASTE ELECTRODE [J].
NAVRATILOVA, Z .
ELECTROANALYSIS, 1991, 3 (08) :799-802
[10]
Mercury analysis in environmental samples by EDXRF and CV-AAS [J].
Nguyen, TH ;
Boman, J ;
Leermakers, M ;
Baeyens, W .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (02) :199-204