Analysis of colloids .9. Investigation of the electrical double layer of colloidal inorganic nanometer-particles by size-exclusion chromatography

被引:25
作者
Fischer, CH [1 ]
Kenndler, E [1 ]
机构
[1] UNIV VIENNA,INST ANALYT CHEM,A-1090 VIENNA,AUSTRIA
关键词
colloids; effective size; inorganic particles; electrical double layer; cadmium sulfide;
D O I
10.1016/S0021-9673(97)00203-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In a liquid containing ions an electrical double layer is formed close to any charged solid surface. Thus a charged dispersed species wears a ''coat'' of ions. In size-exclusion chromatography (SEC) of charged colloidal particles the effective size including this electrical double layer has to be considered. For the investigation of the effective size crystalline colloids with rigid core are advantageous, as their core diameters can be determined by electron microscopy. According to the Gouy-Chapman model the thickness of the double layer is inverse proportional to the square root of the ionic strength of the liquid. Thus the particles investigated (CdS colloids) were chromatographed on the same SEC column with eluents with different ionic strength. It was found that the retention times increased with increasing concentration and valency of the electrolyte present in the eluent. It could be shown that adsorption or repulsion did not play a significant role for this retention time shift as long as the electrolyte content is not too high, The layer thickness and its ionic strength dependence, derived from the SEC experiments with CdS particles in the low nm range were found in good agreement with theory. The sum of diameter of the particle core and the Debye length 1/kappa (as predicted from theory) agreed with effective particle size measured chromatographically.
引用
收藏
页码:179 / 187
页数:9
相关论文
共 32 条
[11]   ANALYSIS OF COLLOIDS .7. WIDE-BORE HYDRODYNAMIC CHROMATOGRAPHY, A SIMPLE METHOD FOR THE DETERMINATION OF PARTICLE-SIZE IN THE NANOMETER-SIZE REGIME [J].
FISCHER, CH ;
GIERSIG, M .
JOURNAL OF CHROMATOGRAPHY A, 1994, 688 (1-2) :97-105
[12]  
FISCHER CH, 1994, J LIQ CHROMATOGR, V17, P1593
[13]   HIGH-SPEED GEL-PERMEATION CHROMATOGRAPHY OF HUMAN THYROGLOBULIN AND SHEEP LIVER ALDEHYDE DEHYDROGENASE [J].
HEARN, MTW ;
GREGO, B ;
BISHOP, CA ;
HANCOCK, WS .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1980, 3 (10) :1549-1560
[15]  
Hiemenz PC, 1986, PRINCIPLES COLLOID S, P677
[16]  
KIRKLAND JJ, 1994, ADV CHEM SER, V234, P287
[17]   HIGH-PERFORMANCE SIZE-EXCLUSION LIQUID-CHROMATOGRAPHY OF INORGANIC COLLOIDS [J].
KIRKLAND, JJ .
JOURNAL OF CHROMATOGRAPHY, 1979, 185 (DEC) :273-288
[18]   A LUMINESCENT SILICON NANOCRYSTAL COLLOID VIA A HIGH-TEMPERATURE AEROSOL REACTION [J].
LITTAU, KA ;
SZAJOWSKI, PJ ;
MULLER, AJ ;
KORTAN, AR ;
BRUS, LE .
JOURNAL OF PHYSICAL CHEMISTRY, 1993, 97 (06) :1224-1230
[19]   SIZE-EXCLUSION CHROMATOGRAPHY OF POLY-ELECTROLYTES - EXPERIMENTAL-EVIDENCE FOR A GENERAL MECHANISM [J].
POTSCHKA, M .
JOURNAL OF CHROMATOGRAPHY, 1988, 441 (02) :239-260
[20]   INTERFACIAL EFFECTS IN SIZE-EXCLUSION CHROMATOGRAPHY OF LATEX [J].
POTSCHKA, M .
JOURNAL OF CHROMATOGRAPHY, 1991, 587 (02) :276-279