Healing process induced by three composite prostheses in the repair of abdominal wall defects

被引:24
作者
Bellón, JM [1 ]
Jurado, F [1 ]
García-Moreno, F [1 ]
Corrales, C [1 ]
Martín, ACS [1 ]
Buján, J [1 ]
机构
[1] Univ Alcala de Henares, Fac Med, Dept Morphol Sci & Surg, Surg Res Lab, Alcala De Henares 28871, Madrid, Spain
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 2002年 / 63卷 / 02期
关键词
prosthesis composite; abdominal wall repair; visceral peritoneum; mesothelium; peritoneal adhesions; mesh repair;
D O I
10.1002/jbm.10123
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The present study compared the performance of three composite prostheses used to repair abdominal wall defects in rabbits. Two of them [Parietex Composit(R) (PC) and Composix(R) (CS)] are commonly used in clinical practice and one was designed by the present team (PL-PU99). At 14 and 90 days postimplant, specimens were obtained for morphological, macrophage response (RAM-11) and morphometric and biomechanical analysis. The prosthetic area covered by adhesions was significantly greater (p < 0.05) in the CS group (6.83 +/- 2.31 cm(2)) than in PC (0.11 +/- 0.02 cm(2)) or PL-PU99 (0.10 +/- 0.07 cm(2)). At 14 days, it was observed a homogeneous, organized, well-vascularized neoperitoneum that was significantly thicker (p < 0.05) in PL-PU99. Except in the CS implants, this layer was covered by a continuous mesothelium. All three composites achieved good recipient tissue integration. Highest macrophage levels were recorded at 14 days with significantly higher values in the PL-PU99 prosthesis. Biomechanical strength was significantly greater (p < 0.05) in CS at two weeks postimplant, but it was similar at 90 days. These findings suggest that the three composites show ideal integration with host tissue, along with similar biomechanical strength at 90 days, and significantly higher adhesion formation is induced by the CS prosthesis, possibly due to incomplete mesothelialization of the lower prosthetic surface. (C) 2002 John Wiley Sons, Inc.
引用
收藏
页码:182 / 190
页数:9
相关论文
共 25 条
[1]   EXPERIMENTAL EVALUATION OF A NEW COMPOSITE MESH WITH THE SELECTIVE PROPERTY OF INCORPORATION TO THE ABDOMINAL-WALL WITHOUT ADHERING TO THE INTESTINES [J].
AMID, PK ;
SHULMAN, AG ;
LICHTENSTEIN, IL ;
SOSTRIN, S ;
YOUNG, J ;
HAKAKHA, M .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (03) :373-375
[2]  
Bellon JM, 1996, J AM COLL SURGEONS, V183, P11
[3]   MACROPHAGE RESPONSE TO EXPERIMENTAL IMPLANTATION OF POLYPROPYLENE PROSTHESES [J].
BELLON, JM ;
BUJAN, J ;
CONTRERAS, L ;
HERNANDO, A ;
JURADO, F .
EUROPEAN SURGICAL RESEARCH, 1994, 26 (01) :46-53
[4]   Evaluation of the acute scarring response to the implant of different types of biomaterial in the abdominal wall [J].
Bellón, JM ;
Contreras, LA ;
Pascual, G ;
Buján, J .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2000, 11 (01) :25-29
[5]   Effect of phosphatidylcholine on the process of peritoneal adhesion following implantation of a polypropylene mesh prosthesis [J].
Bellon, JM ;
Contreras, LA ;
Bujan, J ;
Jurado, F .
BIOMATERIALS, 1996, 17 (14) :1369-1372
[6]  
Bellon JM, 1997, J BIOMED MATER RES, V38, P197
[7]   Interface formed between visceral peritoneum and experimental polypropylene or polytetrafluoroethylene abdominal wall implants [J].
Bellon, JM ;
Bujan, J ;
Contreras, L ;
Hernando, A .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1996, 7 (06) :331-336
[8]  
Bellón JM, 1999, EUR J SURG, V165, P145
[9]   Composite mesh (polypropylene-e-PTFE) in the intraperitoneal positionA report of 30 cases [J].
R. Bendavid .
Hernia, 1997, 1 (1) :5-8
[10]  
CHEW DK, 2000, SURGERY, V125, pS109