Electrocatalytic oxidation of nitric oxide at nano-TiO2/Nafion composite film modified glassy carbon electrode

被引:17
作者
Wang, YZ
Li, CY
Hu, SS [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
[2] Chinese Acad Sci, State Key Lab Transducer Technol, Beijing 100080, Peoples R China
关键词
nitric oxide radical; nanocrystalline TiO2; chemically modified electrode; Nafion;
D O I
10.1007/s10008-005-0010-1
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A novel nanocrystalline TiO2 (nano-TiO2) and Nafion composite film modified glassy carbon electrode has been developed for the determination of nitric oxide (NO) radical in an aqueous solution. This modified electrode can be employed as a NO sensor with a low detection limit, fast response, high sensitivity and selectivity. Two apparent anodic peaks were observed at 0.67 and 0.95 V at the nano-TiO2 modified glassy carbon electrode by differential pulse voltammetry (DPV). After further modification with a thin film of Nafion, which was capable of preventing some anionic interference such as nitrite and ascorbic acid, only one peak appeared and the peak current enhanced greatly. The chronocoulometric experimental results showed NO was oxidized by one-electron transfer reaction at the composite film modified electrode. The amperometric responses increased linearly with the concentrations of NO ranging from 3.6x10(-7) mol/L to 5.4x10(-5) mol/L. The detection limit was estimated to be 5.4x10(-8) mol/L. In this sensor system, the modification film provides complete selectivity for NO over nitrite anions (NO2-).
引用
收藏
页码:383 / 388
页数:6
相关论文
共 19 条
[1]  
Bard A.J., 2001, ELECTROCHEMICAL METH, V2, P210
[2]   Electrochemical nitric oxide sensors for biological samples - Principle, selected examples and applications [J].
Bedioui, F ;
Villeneuve, N .
ELECTROANALYSIS, 2003, 15 (01) :5-18
[3]   THE PHYSIOLOGICAL-ROLE OF NITRIC-OXIDE [J].
BUTLER, AR ;
WILLIAMS, DLH .
CHEMICAL SOCIETY REVIEWS, 1993, 22 (04) :233-241
[4]   THE ELECTRO REDUCTION OF NITRIC-OXIDE ON BULK PLATINUM IN ACID-SOLUTIONS [J].
COLUCCI, JA ;
FORAL, MJ ;
LANGER, SH .
ELECTROCHIMICA ACTA, 1985, 30 (04) :521-528
[5]   ELECTROCHEMICAL BEHAVIOR OF NITRIC-OXIDE IN 4M H2SO4 ON PLATINUM [J].
DUTTA, D ;
LANDOLT, D .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1972, 119 (10) :1320-&
[6]  
Feelish M, 1996, METHODS NITRIC OXIDE
[7]   o-phenylenediamine-modified carbon fiber electrodes for the detection of nitric oxide [J].
Friedemann, MN ;
Robinson, SW ;
Gerhardt, GA .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2621-2628
[8]  
MANLINSKI T, 1992, NATURE, V358, P676
[9]   PREVENTION OF THE RAPID DEGRADATION OF SUBCUTANEOUSLY IMPLANTED AG/AGCL REFERENCE ELECTRODES USING POLYMER-COATINGS [J].
MOUSSY, F ;
HARRISON, DJ .
ANALYTICAL CHEMISTRY, 1994, 66 (05) :674-679
[10]   In vivo nitric oxide sensor using non-conducting polymer-modified carbon fiber [J].
Park, JK ;
Tran, PH ;
Chao, JKT ;
Ghodadra, R ;
Rangarajan, R ;
Thakor, NV .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (11) :1187-1195