Effect of fluoride iontophoresis on the microtensile bond strength between dentin and two adhesive systems

被引:11
作者
Chen, L. -J.
Meng, Q. -F.
Chen, Y. -M. [1 ]
Smales, R. J. [2 ]
Yip, K. H. -K. [3 ]
机构
[1] Nanjing Med Univ, Coll Stomatol, Dent Res Inst, Dept Prosthet Dent, Nanjing 210029, Peoples R China
[2] Univ Adelaide, Sch Dent, Adelaide, SA, Australia
[3] Univ Hong Kong, Fac Dent, Hong Kong, Hong Kong, Peoples R China
关键词
fluoride iontophoresis; microtensile bond strength; image analysis;
D O I
10.1016/j.jdent.2008.04.018
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: To evaluate the effect of fluoride iontophoresis on the microtensile bond strength (MTBS) between coronal dentin and two resin-based adhesive systems, and to measure quantitatively dentinal tubule occlusion. Methods: Twelve freshly extracted intact human mandibular third molars were divided randomly into four groups. The superficial occlusal dentin of each tooth was exposed and treated. Group A1: One-Step Plus total-etch adhesive system; group A2: One-Step Plus total-etch adhesive system after fluoride iontophoresis; group B1: ACE BOND SE self-etching adhesive system; group B2: ACE BOND SE self-etching adhesive system after fluoride iontophoresis. A resin composite buildup was made for each tooth, which was then sectioned along its long axis to produce 10 beams (1.0 mm x 1.0 min) for the microtensile bond strength (MTBS) test. Five dentin disks were cut in half and their occlusal surfaces etched with 6% citric acid. The test halves were treated with fluoride iontophoresis. Four SEM photomicrographs were taken from corresponding sites on each test and each nontreated control half-disk. Image-Pro Plus 4 software quantified the percentage of tubule occlusion. Data were analyzed using one-way ANOVA, X-2 and t-tests, with the probability level set at alpha = 0.05. Results: The mean MTBS (MPa) for each group was, A1: 30.86 (S.D. 6.84); A2: 25.04 (8.49); B1: 19.22 (6.88); B2: 19.40 (6.92). There were significant differences among all groups (P <= 0.02), except between groups B1 and B2 (P = 0.92). Fluoride iontophoresis resulted in significantly increased dentinal tubule occlusion (P < 0.001). Conclusions: Fluoride iontophoresis treatment reduced significantly the dentin bond strength of One-Step Plus total-etch adhesive, but not that of ACE BOND SE self-etching adhesive. However, the bond strength of the former remained significantly higher than that of the latter adhesive system. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:697 / 702
页数:6
相关论文
共 33 条
[1]   DENTIN HYPERSENSITIVITY - A REVIEW .2. CLINICAL AND INVITRO EVALUATION OF TREATMENT AGENTS [J].
ADDY, M ;
DOWELL, P .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1983, 10 (04) :351-363
[2]   In vitro quantification of changes in human dentine tubule parameters using SEM and digital analysis [J].
Ahmed, TR ;
Mordan, NJ ;
Gilthorpe, MS ;
Gillam, DG .
JOURNAL OF ORAL REHABILITATION, 2005, 32 (08) :589-597
[3]   Microtensile bond strength testing and failure analysis of two dentin adhesives [J].
Armstrong, SR ;
Boyer, DB ;
Keller, JC .
DENTAL MATERIALS, 1998, 14 (01) :44-50
[4]  
Brandt P D, 2002, SADJ, V57, P274
[5]  
BRANNSTROM M, 1972, INT DENT J, V22, P219
[6]   Evaluation of micro-tensile, shear and tensile tests determining the bond strength of three adhesive systems [J].
Cardoso, PEC ;
Braga, RR ;
Carrilho, MRO .
DENTAL MATERIALS, 1998, 14 (06) :394-398
[7]   DENTIN HYPERSENSITIVITY - A REVIEW .1. ETIOLOGY, SYMPTOMS AND THEORIES OF PAIN PRODUCTION [J].
DOWELL, P ;
ADDY, M .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1983, 10 (04) :341-350
[8]  
Duke E S, 1991, Am J Dent, V4, P241
[9]   CURRENT STRATEGIES FOR DENTIST-APPLIED TREATMENT IN THE MANAGEMENT OF HYPERSENSITIVE DENTIN [J].
GANGAROSA, LP .
ARCHIVES OF ORAL BIOLOGY, 1994, 39 :S101-S106
[10]   PRACTICAL CONSIDERATIONS IN IONTOPHORESIS OF FLUORIDE FOR DESENSITIZING DENTIN [J].
GANGAROSA, LP ;
PARK, NH .
JOURNAL OF PROSTHETIC DENTISTRY, 1978, 39 (02) :173-178