In vitro quantification of changes in human dentine tubule parameters using SEM and digital analysis

被引:27
作者
Ahmed, TR
Mordan, NJ
Gilthorpe, MS
Gillam, DG
机构
[1] UCL, Eastman Dent Inst Oral Hlth Care Sci, Dept Biomat Sci, Electron Microscopy Unit, London WC1X 8LD, England
[2] Univ Leeds, Ctr Biostat & Epidemiol, Leeds, W Yorkshire, England
关键词
dentine; hypersensitivity; quantification; digital image analysis; scanning electron microscopy; multilevel modelling;
D O I
10.1111/j.1365-2842.2005.01473.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Dentine hypersensitivity is recognized as a pain arising from fluid movement within dentine tubules that are open to the oral environment. Blocking the tubules is considered to be the principal aim of treatment, and the accurate assessment of tubule occlusion is the primary goal of many in vitro studies. This assessment usually comprises either measuring tubule permeability or scanning electron microscope examination of the dentine surface. Several scanning microscopy studies have claimed to quantify tubule occlusion, but are descriptive, qualitative or semi-quantitative evaluations. The present study was undertaken to assess the use of digital image analysis in quantifying the effectiveness of a selected desensitizing agent from micrographs of control and treated dentine surfaces. Using a dentine disc model, an accurate methodology was sought to investigate the occluding potential of Butler Protect (J.O. Butler, Chicago, IL, USA). Subjective examination of the images indicated there was little difference after a single application, but considerable effect after 20 applications. Quantitative digital analysis of a test image, demonstrated reproducibility between two examiners when used in fully- and semi-automated mode. After a single application of Butler Protect, multilevel statistical modelling demonstrated decreases in tubule area and maximum, minimum and mean diameter measurements (P < 0.001), whereas single level analysis showed increases in area and maximum and mean diameters. Multiple application of Butler Protect demonstrated even greater decreases in all parameters (P < 0.001). This quantitative methodology was reproducible between examiners and, when combined with good controls and multilevel statistical modelling, was able to discriminate a single application of desensitizing agent.
引用
收藏
页码:589 / 597
页数:9
相关论文
共 25 条
[1]   DENTIN HYPERSENSITIVITY - UPTAKE OF TOOTHPASTES ONTO DENTIN AND EFFECTS OF BRUSHING, WASHING AND DIETARY ACID - SEM IN-VITRO STUDY [J].
ABSI, EG ;
ADDY, M ;
ADAMS, D .
JOURNAL OF ORAL REHABILITATION, 1995, 22 (03) :175-182
[2]   DENTIN HYPERSENSITIVITY - THE EFFECT OF TOOTHBRUSHING AND DIETARY COMPOUNDS ON DENTIN INVITRO - AN SEM STUDY [J].
ABSI, EG ;
ADDY, M ;
ADAMS, D .
JOURNAL OF ORAL REHABILITATION, 1992, 19 (02) :101-110
[3]  
Addy M., 1985, Proceedings of symposium on hypersensitive dentin-origin and management, P147
[4]   THE DIAMETER OF DENTINAL TUBULES IN HUMAN CORONAL DENTIN AFTER DEMINERALIZATION AND AIR-DRYING - A COMBINED LIGHT-MICROSCOPY AND SEM STUDY [J].
ARENDS, J ;
STOKROOS, I ;
JONGEBLOED, WG ;
RUBEN, J .
CARIES RESEARCH, 1995, 29 (02) :118-121
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]  
Borem L M, 1994, Quintessence Int, V25, P283
[7]   SCANNING ELECTRON-MICROSCOPIC INVESTIGATION OF HUMAN DENTINAL TUBULES [J].
GARBEROGLIO, R ;
BRANNSTROM, M .
ARCHIVES OF ORAL BIOLOGY, 1976, 21 (06) :355-362
[8]   The effects of oxalate-containing products on the exposed dentine surface: an SEM investigation [J].
Gillam, DG ;
Mordan, NJ ;
Sinodinou, AD ;
Tang, JY ;
Knowles, JC ;
Gibson, IR .
JOURNAL OF ORAL REHABILITATION, 2001, 28 (11) :1037-1044
[9]   Comparison of dentine hypersensitivity in selected occidental and oriental populations [J].
Gillam, DG ;
Seo, HS ;
Newman, HN ;
Bulman, JS .
JOURNAL OF ORAL REHABILITATION, 2001, 28 (01) :20-25
[10]  
Gillam DG, 1997, ENDOD DENT TRAUMATOL, V13, P36