A comparison of coplanar four-field techniques for conformal radiotherapy of the prostate

被引:40
作者
Bedford, JL
Khoo, VS
Oldham, M
Dearnaley, DP
Webb, S
机构
[1] Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Trust, Sutton SM2 5PT, Surrey, England
[3] Inst Canc Res, Acad Dept Radiotherapy & Oncol, Sutton SM2 5PT, Surrey, England
[4] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI 48073 USA
关键词
conformal radiotherapy; prostate cancer; seminal vesicles; rectum; dose-volume histogram; treatment planning optimisation;
D O I
10.1016/S0167-8140(99)00057-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Conformal radiotherapy of the prostate is an increasingly common technique, but the optimal choice of beam configuration remains unclear. This study systematically compares a number of coplanar treatment plans for four-field irradiation of two different clinical treatment volumes: prostate only (PO) and the prostate plus seminal vesicles (PSV). Materials and methods: A variety of four-field coplanar treatment plans were created for PO and PSV volumes in each of ten patients. Plans included a four-field 'box' plan, a symmetric plan having bilateral anterior and posterior oblique fields, a plan with anterior oblique and lateral fields. a series of asymmetric plans, and a three-field plan having anterior and bilateral fields for comparison, Doses of 64 and 74 Gy were prescribed to the isocentre. Plans were compared using the volume of rectum irradiated to greater than 50% (V-50), 80% (V-80) and 90% (V-90) of the prescribed dose. Tumour control probabilities (TCP) and normal tissue complication probabilities (NTCP) for the rectum, bladder and femoral heads were also evaluated. femoral head dose was limited such that less than 10% of each femoral head received 70% of the prescribed dose. Results: For the PO group, the optimal plan consisted of anterior oblique and lateral fields (Rectal V-80 = 23.8 +/- 5.0% (1 SD)), while the box technique (V-80 = 26.0 +/- 5.8%) was less advantageous in terms of rectal sparing (P = 0.001). Similar results were obtained for the PSV group (Rectal V-80 = 43.9 +/- 5.0% and 47.3 +/- 5.5% for the two plan types, respectively, P = 0.001). The three-held plan was comparable to the optimal four-field plan but gave higher superficial body dose. With dose escalation from 64 to 74 Gy, the mean TCP for the optimal plan rose from 52.0 +/- 2.8% to 74.1 +/- 2.0%. Meanwhile, rectal NTCP for the optimal plan rose by 3.5% (PO) or 8.4% (PSV), compared to 4.7% (PO) or 10.1% (PSV) for the box plan, Conclusions: For PO volumes, a plan with gentry angles of 35 degrees, 90 degrees, 270 degrees and 325 degrees offers a high level of rectal sparing and acceptable dose to the femoral heads for all patients, while for PSV volumes, the corresponding plan has gantry angles of 20 degrees, 90 degrees, 270 degrees and 340 degrees. Using these plans, the gain in TCP resulting from dose escalation can be achieved with a smaller increase in anticipated rectal NTCP. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:225 / 235
页数:11
相关论文
共 31 条
[21]   THE ROYAL-MARSDEN-HOSPITAL PELVIC RADIOTHERAPY TRIAL - TECHNICAL ASPECTS AND QUALITY ASSURANCE [J].
MAYLES, WPM ;
CHOW, M ;
DYER, J ;
FERNANDEZ, EM ;
HEISIG, S ;
KNIGHT, RT ;
MOORE, I ;
NAHUM, AE ;
SHENTALL, GS ;
TAIT, DM .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :184-191
[22]   COMPARISON OF A CONFORMAL NONAXIAL BOOST WITH A 4-FIELD BOOST TECHNIQUE IN THE TREATMENT OF ADENOCARCINOMA OF THE PROSTATE [J].
MESINA, CF ;
SHARMA, R ;
RISSMAN, LS ;
GEERING, L ;
HE, TM ;
FORMAN, JD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (02) :427-430
[23]  
Nahum AE, 1992, ADV RAD THERAPY TUMO, P425
[24]   COMPARISON OF TREATMENT TECHNIQUES FOR CONFORMAL RADIOTHERAPY OF THE PROSTATE USING DOSE-VOLUME HISTOGRAMS AND NORMAL TISSUE COMPLICATION PROBABILITIES [J].
NEAL, AJ ;
OLDHAM, M ;
DEARNALEY, DP .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (01) :29-34
[25]   The optimisation of wedge filters in radiotherapy of the prostate [J].
Oldham, M ;
Neal, AJ ;
Webb, S .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (03) :209-220
[26]   A COMPARISON OF CONVENTIONAL FORWARD PLANNING WITH INVERSE PLANNING FOR 3D CONFORMAL RADIOTHERAPY OF THE PROSTATE [J].
OLDHAM, M ;
NEAL, A ;
WEBB, S .
RADIOTHERAPY AND ONCOLOGY, 1995, 35 (03) :248-262
[27]   EFFECTIVE WEDGE ANGLES WITH A UNIVERSAL WEDGE [J].
PETTI, PL ;
SIDDON, RL .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (09) :985-991
[28]  
Pickett B, 1994, Med Dosim, V19, P237
[29]   Improvements in prostate radiotherapy from the customization of beam directions [J].
Rowbottom, CG ;
Webb, S ;
Oldham, M .
MEDICAL PHYSICS, 1998, 25 (07) :1171-1179
[30]   The delta-TCP concept: A clinically useful measure of tumor control probability [J].
Sanchez-Nieto, B ;
Nahum, AE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (02) :369-380