pH-induced hysteretic gating of track-etched polycarbonate membranes ( TEPC) has been achieved by depositing layer-by-layer assembled polyelectrolyte multilayers comprising poly( allylamine hydrochloride) ( PAH) and poly( sodium 4-styrenesulfonate) ( PSS) at a high pH condition ( pH > 9.0). Scanning electron microscopy and transmission electron microscopy showed that the average bilayer thickness of multilayers was greater within the cylindrical pores of track-etched polycarbonate membranes compared to the multilayers on planar substrates ( e. g., Si wafers and the face of TEPC membranes). Swelling/deswelling properties of multilayers and gating properties of the multilayer-modified TEPC membranes were studied by measuring the flux of pH-adjusted deionized water. Large discontinuous changes in the transmembrane flux were observed, indicating that the multilayers within the cylindrical pores of TEPC membranes exhibit the discontinuous swelling/deswelling behavior observed previously for planar systems. The degree of swelling as estimated by simple models, however, showed that ( PAH/PSS) multilayers in the confined geometry swelled to smaller extents compared to the same multilayers on planar substrates under the same conditions. Multilayer-modified membranes showed reversible gating properties as the pH condition of feed solution was alternated between pH 2.5 and 10.5. In situ atomic force microscopy ( AFM) was used to visualize the closing of the pores as a function of time. The hysteretic gating property of the multilayer-modified TEPC membrane was utilized to achieve either a "closed" or "open" state at one pH condition depending on the pretreatment history, thereby enabling either the retention or passage of high-molecular weight polymers by varying the membrane pretreatment condition.
引用
收藏
页码:8521 / 8529
页数:9
相关论文
共 70 条
[11]   Influence of the degree of ionization on weak polyelectrolyte multilayer assembly [J].
Choi, J ;
Rubner, MF .
MACROMOLECULES, 2005, 38 (01) :116-124
[12]   Negatively thermoresponsive membranes with functional gates driven by zipper-type hydrogen-bonding interactions [J].
Chu, LY ;
Li, Y ;
Zhu, JH ;
Chen, WM .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2005, 44 (14) :2124-2127
[13]  
Chu LY, 2002, ADV MATER, V14, P386, DOI 10.1002/1521-4095(20020304)14:5<386::AID-ADMA386>3.0.CO
[14]  
2-I
[15]   Diffusion of labeled polyelectrolyte probes in unlabeled polyelectrolyte matrix solutions [J].
Cong, R ;
Temyanko, E ;
Russo, PS .
MACROMOLECULES, 2005, 38 (26) :10627-10630
[16]  
Decher G., 2003, Multilayer Thin Films Sequential Assembly of Nanocomposite Materials
[17]   PH-responsive properties of hollow polyelectrolyte microcapsules templated on various cores [J].
Déjugnat, C ;
Sukhorukov, GB .
LANGMUIR, 2004, 20 (17) :7265-7269
[18]   Adsorption of polyelectrolyte multilayers on polymer surfaces [J].
Delcorte, A ;
Bertrand, P ;
Wischerhoff, E ;
Laschewsky, A .
LANGMUIR, 1997, 13 (19) :5125-5136
[19]  
Denn M., 1980, PROCESS FLUID MECH
[20]  
Donath E, 1998, ANGEW CHEM INT EDIT, V37, P2202, DOI 10.1002/(SICI)1521-3773(19980904)37:16<2201::AID-ANIE2201>3.0.CO