Disposable screen-printed electrodes for the immunochemical detection of polychlorinated biphenyls

被引:60
作者
DelCarlo, M [1 ]
Lionti, I [1 ]
Taccini, M [1 ]
Cagnini, A [1 ]
Mascini, M [1 ]
机构
[1] UNIV FLORENCE,DIPARTIMENTO SANITA PUBBL EPIDEMIOL & CHIM ANAL A,SEZ CHIM ANALIT,I-50121 FLORENCE,ITALY
关键词
differential pulse voltammetry; immunoassay; alkaline phosphatase; screen-printed electrode;
D O I
10.1016/S0003-2670(96)00627-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three different electrochemical approaches for the detection of cr-naphthol (amperometry, chronoamperometry and differential pulse voltammetry), using screen-printed carbon electrodes, were compared with respect to measurable range, detection limit, reproducibility, sample throughput and suitability for in field use. The highest sensitivity (252 nA/mu M) with a calculated detection limit of 0.1 mu M, combined with a remarkable 'time for sample measurement' (5.5 s) was achieved with differential pulse voltammetry. The standard error over the whole measured range (0.5-100 mu M) was below 5%. The scan speed and the pulse amplitude of the differential pulse voltammetric method were optimised using a simplex method. The optimised electrochemical procedure was then used to evaluate the detection of low levels of alkaline phosphatase: this enzyme catalyses the hydrolysis of alpha-naphthol phosphate to alpha-naphthol. Using 2 min as incubation time for the enzyme reaction, a linear calibration curve in the range 1-10(-5) U/ml was obtained with a calculated detection limit of 2.1 x 10(-6)U/ml. The standard error for the 10(-2)U/ml enzyme standard was 6.8%. Finally a competitive enzyme immunoassay for polychlorinated biphenyls based on alkaline phosphatase was performed using the optimised electrochemical detection of alpha-naphthol. The assay measurable range was 0.01-10 mu g/ml, and the detection limit was 0.01 mu g/ml (B-x/B-o%=10).
引用
收藏
页码:189 / 197
页数:9
相关论文
共 32 条
[1]  
ADAMS MJ, 1992, PRACTICAL GUIDE CHEM, P181
[2]  
ALVAREZICAZA M, 1993, ANAL CHEM, V65, P525
[3]   AVIDIN-BIOTIN BASED ELECTROCHEMICAL IMMUNOASSAY FOR THYROTROPIN [J].
ATHEY, D ;
BALL, M ;
MCNEIL, CJ .
ANNALS OF CLINICAL BIOCHEMISTRY, 1993, 30 :570-577
[4]  
BEH S K, 1989, Analytical Proceedings, V26, P290
[5]   GLUCOSE BIOSENSORS BASED ON THICK-FILM TECHNOLOGY [J].
BILITEWSKI, U ;
RUGER, P ;
SCHMID, RD .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (04) :369-373
[6]   Ruthenized screen-printed choline oxidase-based biosensors for measurement of anticholinesterase activity [J].
Cagnini, A ;
Palchetti, I ;
Mascini, M ;
Turner, APF .
MIKROCHIMICA ACTA, 1995, 121 (1-4) :155-166
[7]   AN ELECTROCHEMICAL IMMUNOASSAY FOR CLOSTRIDIUM-PERFRINGENS PHOSPHOLIPASE-C [J].
CARDOSI, M ;
BIRCH, S ;
TALBOT, J ;
PHILLIPS, A .
ELECTROANALYSIS, 1991, 3 (03) :169-176
[8]   SCREEN PRINTED GLUCOSE ELECTRODES BASED ON PLATINIZED CARBON PARTICLES AND GLUCOSE-OXIDASE [J].
CARDOSI, MF ;
BIRCH, SW .
ANALYTICA CHIMICA ACTA, 1993, 276 (01) :69-74
[9]  
DELCARLIO M, 1996, IN PRESS ANAL CHIM A
[10]  
DELLACIANA L, 1995, J ELECTROANAL CHEM, V38, P129