Modelling of particle paths passing through an ultrasonic standing wave

被引:81
作者
Townsend, RJ [1 ]
Hill, M [1 ]
Harris, NR [1 ]
White, NM [1 ]
机构
[1] Univ Southampton, Sch Engn Sci, Electromagnet Res Grp, Southampton SO17 1BJ, Hants, England
关键词
radiation force; CFD; standing waves; concentration;
D O I
10.1016/j.ultras.2004.01.025
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Within an ultrasonic standing wave particles experience acoustic radiation forces causing agglomeration at the nodal planes of the wave. The technique can be used to agglomerate, suspend, or manipulate particles within a flow. To control agglomeration rate it is important to balance forces on the particles and, in the case where a fluid/particle mix flows across the applied acoustic field, it is also necessary to optimise fluid flow rate. To investigate the acoustic and fluid forces in such a system a particle model has been developed, extending an earlier model used to characterise the 1-dimensional field in a layered resonator. In order to simulate fluid drag forces, CFD software has been used to determine the velocity profile of the fluid/particle mix passing through the acoustic device. The profile is then incorporated into a MATLAB model. Based on particle force components, a numerical approach has been used to determine particle paths. Using particle coordinates, both particle concentration across the fluid channel and concentration through multiple outlets are calculated. Such an approach has been used to analyse the operation of a microfluidic flow-through separator, which uses a half wavelength standing wave across the main channel of the device. This causes particles to converge near the axial plane of the channel, delivering high and low particle concentrated flow through two outlets, respectively. By extending the model to analyse particle separation over a frequency range, it is possible to identify the resonant frequencies of the device and associated separation performance. This approach will also be used to improve the geometric design of the microengineered fluid channels, where the particle model can determine the limiting fluid flow rate for separation to occur, the value of which is then applied to a CFD model of the device geometry. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:319 / 324
页数:6
相关论文
共 14 条
[1]   Study on the bubble motion control by ultrasonic wave [J].
Abe, Y ;
Kawaji, M ;
Watanabe, T .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2002, 26 (6-7) :817-826
[2]   Analytical scale ultrasonic standing wave manipulation of cells and microparticles [J].
Coakley, WT ;
Hawkes, JJ ;
Sobanski, MA ;
Cousins, CM ;
Spengler, J .
ULTRASONICS, 2000, 38 (1-8) :638-641
[3]  
Groschl M, 1998, ACUSTICA, V84, P432
[4]   FRACTIONATION OF MIXED PARTICULATE SOLIDS ACCORDING TO COMPRESSIBILITY USING ULTRASONIC STANDING-WAVE FIELDS [J].
GUPTA, S ;
FEKE, DL ;
MANAS-ZLOCZOWER, I .
CHEMICAL ENGINEERING SCIENCE, 1995, 50 (20) :3275-3284
[5]   Force field particle filter, combining ultrasound standing waves and laminar flow [J].
Hawkes, JJ ;
Coakley, WT .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 75 (03) :213-222
[6]   Modelling of layered resonators for ultrasonic separation [J].
Hill, M ;
Shen, YJ ;
Hawkes, JJ .
ULTRASONICS, 2002, 40 (1-8) :385-392
[7]   Modelling in the design of a flow-through ultrasonic separator [J].
Hill, M ;
Wood, RJK .
ULTRASONICS, 2000, 38 (1-8) :662-665
[8]   The use of ultrasonic standing waves to enhance optical particle sizing equipment [J].
Holwill, ILJ .
ULTRASONICS, 2000, 38 (1-8) :650-653
[9]   Methodology for fractionating suspended particles using ultrasonic standing wave and divided flow fields [J].
Johnson, DA ;
Feke, DL .
SEPARATIONS TECHNOLOGY, 1995, 5 (04) :251-258
[10]   Field-assisted extraction of cells, particles and macromolecules [J].
Karumanchi, RSMS ;
Doddamane, SN ;
Sampangi, C ;
Todd, PW .