Determination of DL-tetrahydropalmatine in Corydalis yanhusuo by L-tetrahydropalmatine imprinted monolithic column coupling with reversed-phase high performance liquid chromatography

被引:125
作者
Ou, Junjie [1 ]
Kong, Liang [1 ]
Pan, Chensong [1 ]
Su, Xingye [1 ]
Lei, Xiaoyuan [1 ]
Zou, Hanfa [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Natl Chromatog R&A Ctr, Dalian 116023, Peoples R China
基金
中国国家自然科学基金;
关键词
molecularly imprinted polymer; monolithic column; tetrahydropalmatine; chiral separation; on-line; solid-phase extraction; Corydalis yanhusuo;
D O I
10.1016/j.chroma.2006.03.084
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method for direct determination of DL-tetrahydropalmatine (DL-THP) in Corydalis yanhusuo, a traditional Chinese herb, by L-THP imprinted monolithic precolumn on-line/off-line coupling with reversed-phase high performance liquid chromatography (RP-HPLC) was developed. The L-THP imprinted monolithic column has been prepared by in situ polymerization using methacrylic acid (MAA) and ethylene dimethacrylate (EDMA) as functional monomer and cross-linker, respectively. With the optimization of chromatographic conditions, such as mobile phase composition, flow rate, column temperature and sample loading, for the separation of enantiomer, DL-THP was base-line separated on the MIP. The imprinted monolithic column was used as a precolumn for fractionation of the C. yanhusuo extract. Both the non-retained and retained fractions were separated by RP-HPLC. Meanwhile, the D-THP and L-THP can be detected in the non-retained and retained fractions, respectively. Additionally, direct determination of L-THP using molecularly imprinted monolith on-line coupling with a reversed-phase column was acquired. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:163 / 169
页数:7
相关论文
共 40 条
[1]   Study of the nature of recognition in molecularly imprinted polymers, II [1] - Influence of monomer-template ratio and sample load on retention and selectivity [J].
Andersson, HS ;
Karlsson, JG ;
Piletsky, SA ;
Koch-Schmidt, AC ;
Mosbach, K ;
Nicholls, IA .
JOURNAL OF CHROMATOGRAPHY A, 1999, 848 (1-2) :39-49
[2]   Molecularly imprinted solid-phase extraction sorbent for the clean-up of chlorinated phenoxyacids from aqueous samples [J].
Baggiani, C ;
Giovannoli, C ;
Anfossi, L ;
Tozzi, C .
JOURNAL OF CHROMATOGRAPHY A, 2001, 938 (1-2) :35-44
[3]   Use of molecularly imprinted solid-phase extraction for the selective clean-up of clenbuterol from calf urine [J].
Berggren, C ;
Bayoudh, S ;
Sherrington, D ;
Ensing, K .
JOURNAL OF CHROMATOGRAPHY A, 2000, 889 (1-2) :105-110
[4]   On-line solid-phase extraction of triazine herbicides using a molecularly imprinted polymer for selective sample enrichment [J].
Bjarnason, B ;
Chimuka, L ;
Ramström, O .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :2152-2156
[5]   Non-covalent and semi-covalent molecularly imprinted polymers for selective on-line solid-phase extraction of 4-nitrophenol from water samples [J].
Caro, E ;
Masqué, M ;
Marcé, RM ;
Borrull, F ;
Cormack, PAG ;
Sherrington, DC .
JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) :169-178
[6]   Retention mechanism of analytes in the solid-phase extraction process using molecularly imprinted polymers - Application to the extraction of triazines from complex matrices [J].
Chapuis, F ;
Pichon, V ;
Lanza, F ;
Sellergren, B ;
Hennion, MC .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 804 (01) :93-101
[7]   Molecularly imprinted solid-phase extraction of (-)-ephedrine from Chinese Ephedra [J].
Dong, XC ;
Wei, WA ;
Ma, SJ ;
Sun, H ;
Li, Y ;
Guo, JQ .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1070 (1-2) :125-130
[8]   A direct comparison of the performance of ground, beaded and silica-grafted MIPs in HPLC and Turbulent Flow Chromatography applications [J].
Fairhurst, RE ;
Chassaing, C ;
Venn, RF ;
Mayes, AG .
BIOSENSORS & BIOELECTRONICS, 2004, 20 (06) :1098-1105
[9]   Validation of new solid-phase extraction materials for the selective enrichment of organic contaminants from environmental samples [J].
Ferrer, I ;
Barceló, D .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (03) :180-192
[10]   Retentivity and enantioselectivity of uniformly sized molecularly imprinted polymers for d-chlorpheniramine and -brompheniramine in hydro-organic mobile phases [J].
Haginaka, J ;
Kagawa, C .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 804 (01) :19-24