A 55-year-old male with persisting aorto-right ventricular paraprosthetic leak after mitroaortic valve replacement was hospitalized for recurrent heart failure. Depressed left ventricular ejection fraction and severe pulmonary hypertension with increased right and left ventricular filling pressures were associated with significant left to right shunting through the leak. Elective closure of the leak was obtained with a 6-4 mm Amplatzer duct occluder. No complications were observed, and the patient experienced complete resolution of heart failure symptoms, with NYHA class I heart failure 12 months after discharge. (C) 2006 Wiley-Liss, Inc.
引用
收藏
页码:976 / 980
页数:5
相关论文
共 23 条
[1]  
Arora Ramesh, 2004, J Interv Cardiol, V17, P53, DOI 10.1111/j.1540-8183.2004.01714.x
[2]  
Arora Ramesh, 2003, J Interv Cardiol, V16, P83, DOI 10.1046/j.1540-8183.2003.08006.x
[3]   Initial human experience with the Amplatzer perimembranous ventricular septal occluder device [J].
Bass, JL ;
Kalra, GS ;
Arora, R ;
Masura, J ;
Gavora, P ;
Thanopoulos, BD ;
Torres, W ;
Sievert, H ;
Carminati, M ;
Fischer, G ;
Ewert, P .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 58 (02) :238-245
[4]  
BOUJEMLINE Y, 2002, ARCH MAL COEUR VAISS, V95, P483
[5]   Comparison of transcatheter closure of secundum atrial septal defect using the Amplatzer septal occluder associated with deficient versus sufficient rims [J].
Du, ZD ;
Koenig, P ;
Cao, DL ;
Waight, D ;
Heitschmidt, M ;
Hijazi, ZM .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (08) :865-869
[6]  
Ebeid M R, 2001, J Interv Cardiol, V14, P33
[7]   Percutaneous closure of a ruptured sinus of Valsalva aneurysm using the Amplatzer Duct Occluder [J].
Fedson, S ;
Jolly, N ;
Lang, RM ;
Hijazi, ZM .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 58 (03) :406-411
[8]  
Fernández FJ, 2004, REV ESP CARDIOL, V57, P585
[9]   Paravalvular leakage after mitral valve replacement:: improved long-term survival with aggressive surgery? [J].
Genoni, M ;
Franzen, D ;
Vogt, P ;
Seifert, B ;
Jenni, R ;
Künzli, A ;
Niederhäuser, U ;
Turina, M .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (01) :14-19
[10]   Outcomes 15 years after valve replacement with a mechanical versus a bioprosthetic valve: Final report of the Veterans Affairs randomized trial [J].
Hammermeister, K ;
Sethi, GK ;
Henderson, WG ;
Grover, FL ;
Oprian, C ;
Rahimtoola, SH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (04) :1152-1158