Reduced variability in cup positioning: the direct anterior surgical approach using navigation

被引:20
作者
Nogler, Michael [1 ]
Mayr, Eckart [1 ]
Krismer, Martin [1 ]
Thaler, Martin [1 ]
机构
[1] Med Univ Innsbruck, Dept Orthoped, Innsbruck, Austria
关键词
D O I
10.1080/17453670810016867
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose Correct positioning of the acetabular component is important in total hip arthroplasty (THA). We evaluated the effect of an imageless navigation system on the accuracy of cup positioning using a minimally invasive direct anterior approach. Methods Hip replacements were performed in 44 cadaveric hips (22 cadavers) that were divided randomly into 2 groups. In the study group, THA was performed using an imageless navigation system. In the control group, no navigation system was used. CT scans were taken postoperatively. Using 3D reconstructions, the cup position was determined in relation to the frontal pelvic plane. The goal was to place each cup at 45 of inclination and 20 of anteversion, as recommended by the manufacturer. Results In the navigated group, there was a statistically significantly smaller range of deviation from the target angles of inclination and anteversion relative to the control group. Interpretation We conclude that imageless navigation improves the accuracy of cup placement in minimally invasive THA using the direct anterior approach.
引用
收藏
页码:789 / 793
页数:5
相关论文
共 12 条
[1]
Economic considerations in minimally invasive total joint arthroplasty [J].
Bozic, Kevin J. ;
Beringer, Don .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (463) :20-25
[2]
Mini-incision technique for total hip arthroplasty with navigation [J].
DiGioia, AM ;
Plakseychuk, AY ;
Levison, TJ ;
Jaramaz, B .
JOURNAL OF ARTHROPLASTY, 2003, 18 (02) :123-128
[3]
GLASER D, 2007, CLIN BIOMEC IN PRESS
[4]
Anterior approach for total hip arthroplasty: Beyond the minimally invasive technique [J].
Kennon, R ;
Keggi, J ;
Zatorski, LE ;
Keggi, KJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A :91-97
[5]
Leenders T, 2002, Comput Aided Surg, V7, P99, DOI 10.1002/igs.10033
[6]
Effects of Anterolateral Minimally Invasive Surgery in Total Hip Arthroplasty on Hip Muscle Strength, Walking Speed, and Functional Score [J].
Lin, Da-Hon ;
Jan, Mei-Hwa ;
Liu, Tang-Kue ;
Lin, Yeong-Fwu ;
Hou, Sheng-Mou .
JOURNAL OF ARTHROPLASTY, 2007, 22 (08) :1187-1192
[7]
Single-incision anterior approach for total hip arthroplasty on an orthopaedic table [J].
Matta, JM ;
Shahrdar, C ;
Ferguson, T .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) :115-124
[8]
Reduced variability of acetabular cup positioning with use of an imageless navigation system [J].
Nogler, M ;
Kessler, O ;
Prassl, A ;
Donnelly, B ;
Streicher, R ;
Sledge, JB ;
Krismer, M .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) :159-163
[9]
Nogler Michael, 2004, Surg Technol Int, V12, P259
[10]
Computer-assisted surgery for acetabular cup positioning in total hip arthroplasty: comparative prospective randomized study [J].
Parratte, S. ;
Argenson, J.-N. ;
Flecher, X. ;
Aubaniac, J.-M. .
REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2007, 93 (03) :238-246