Mini-incision technique for total hip arthroplasty with navigation

被引:197
作者
DiGioia, AM
Plakseychuk, AY
Levison, TJ
Jaramaz, B
机构
[1] Western Penn Hosp, Inst Comp Assisted Orthopaed Surg, Pittsburgh, PA 15242 USA
[2] Univ Pittsburgh, Med Ctr, Dept Orthopaed Surg, Pittsburgh, PA USA
关键词
total hip arthroplasty; surgical technique; computer-assisted surgery; navigation; minimally invasive;
D O I
10.1054/arth.2003.50025
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This prospective study compares a mini-incision technique and traditional posterior approach for total hip arthroplasty (THA). Thirty-three patients who had undergone a mini-incision THA were matched by diagnosis, gender, average age, and preoperative Harris Hip Score (HHS) to 33 patients who had undergone THA using the traditional posterior approach. The average length of the incision for group 1 was 11.7 cm (range, 7.3-13.0) and for group 2 was 20.2 cm (range, 14.8-26.0). At the 3-month follow-up, patients in the mini-incision group had significant improvement in limp (P<.05) and ability to climb stairs (P<.01) compared with the traditional group. At the 6 month follow-up, the mini-incision group was significantly better in terms of limp (P<.05), distance walked (P<.001), and stairs (P<0.001). There was no significant difference between groups for pain, function, or range of motion at the 1-year follow-up examination.
引用
收藏
页码:123 / 128
页数:6
相关论文
共 26 条
[1]  
AHRENGART L, 1993, CLIN ORTHOP RELAT R, P153
[2]   An analysis of blood management in patients having a total hip or knee arthroplasty [J].
Bierbaum, BE ;
Callaghan, JJ ;
Galante, JO ;
Rubash, HE ;
Tooms, RE ;
Welch, RB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01) :2-10
[3]   Incidence and risk factors for allogenic blood transfusion during major joint replacement using an integrated autotransfusion regimen [J].
Borghi, B ;
Casati, A .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2000, 17 (07) :411-417
[4]   ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[5]  
BUGBEE WD, 1998, ADULT HIP, P1023
[6]   Comparison of a mechanical acetabular alignment guide with computer placement of the socket [J].
DiGioia, AM ;
Jaramaz, B ;
Plakseychuk, AY ;
Moody, JE ;
Nikou, C ;
LaBarca, RS ;
Levison, TJ ;
Picard, F .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :359-364
[7]  
DIGIOIA AM, 1998, CLIN ORTHOP RELAT R, V354, P8
[8]  
Eggli S, 2000, Acta Orthop Belg, V66, P174
[9]  
GUERRA JJ, 1995, CLIN ORTHOP RELAT R, V315, P212
[10]  
HARKESS WJ, 1992, CAMPBELLS ORTHOPAEDI