Simultaneous determination of nitrite and nitrate by normal phase ion-pair liquid chromatography

被引:111
作者
Butt, SB
Riaz, M
Iqbal, MZ
机构
[1] PINSTECH, Cent Analyt Facil, Islamabad, Pakistan
[2] PINSTECH, Div Nucl Chem, Islamabad, Pakistan
[3] Univ Punjab, Inst Chem, Lahore, Pakistan
关键词
nitrite; chromatography; separation;
D O I
10.1016/S0039-9140(01)00502-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Normal phase ion-pair high performance liquid chromatography has been used for simultaneous separation of nitrite and nitrate using tetraethylammonium (TEA)(+) as ion-pairing reagent. The concentration effect of (TEA)(+), buffer salt and pH of the eluent on separation is investigated. The UV detector response at various wavelengths has been optimized. The performance of the proposed method is compared with ion chromatography for quantification of the anions in potable water, wastewater and in food samples, such as spinach and lettuce. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:789 / 797
页数:9
相关论文
共 19 条
[1]  
BUIDT A, 1999, ANAL CHEM, V71, P3003
[2]   Simultaneous assay of copper iron and uranium in phosphate media by ion-pair liquid chromatography [J].
Butt, SB ;
Riaz, M ;
UlHaq, E .
CHROMATOGRAPHIA, 1996, 42 (1-2) :34-38
[3]   Trace level determination ion iron in high purity copper by ion pair liquid chromatography [J].
Butt, SB ;
Riaz, M ;
Waqar, F ;
Jan, S ;
Haq, EU .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (06) :843-853
[4]   ION-PAIR CHROMATOGRAPHY OF ACIDIC DRUG METABOLITES AND ENDOGENIC COMPOUNDS [J].
FRANSSON, B ;
WAHLUND, KG ;
JOHANSSON, IM ;
SCHILL, G .
JOURNAL OF CHROMATOGRAPHY, 1976, 125 (01) :327-344
[5]   Enzymatic spectrophotometric determination of nitrites in beer [J].
Girotti, S ;
Ferri, EN ;
Fini, F ;
Ruffini, F ;
Budini, R ;
Moura, I ;
Almeida, G ;
Costa, C ;
Moura, JJG ;
Carrea, G .
ANALYTICAL LETTERS, 1999, 32 (11) :2217-2227
[6]  
GLATTSTEIN B, 1986, 2 INT S AN DET EXPL
[7]  
HEAD PC, 1985, HDB PRACTICAL ESTUAR
[8]   Potentiometric detection of monovalent anions separated by ion chromatography using all solid-state contact PVC matrix membrane electrode [J].
Isildak, I .
CHROMATOGRAPHIA, 1999, 49 (5-6) :338-342
[9]   Simultaneous detection of monovalent anions and cations using all solid-state contact PVC membrane anion and cation-selective electrodes as detectors in single column ion chromatography [J].
Isildak, I ;
Asan, A .
TALANTA, 1999, 48 (04) :967-978
[10]   DETERMINATION OF NITRATE AND NITRITE IN CURED MEATS USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
JACKSON, PE ;
HADDAD, PR ;
DILLI, S .
JOURNAL OF CHROMATOGRAPHY, 1984, 295 (02) :471-478