Effect of the rate of gadolinium injection on magnetic resonance pulmonary perfusion imaging

被引:21
作者
Matsuoka, S [1 ]
Uchiyama, K [1 ]
Shima, H [1 ]
Terakoshi, H [1 ]
Oishi, S [1 ]
Nojiri, Y [1 ]
Ogata, H [1 ]
机构
[1] Teikyo Univ, Sch Med, Ichihara Hosp, Dept Radiol, Chiba 2990111, Japan
关键词
pulmonary; lung perfusion; magnetic resonance imaging (MRI); contrast agent injection rate; pulmonary circulation;
D O I
10.1002/jmri.10038
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine whether the injection rate of contrast agent affects the dynamics of enhancement of the pulmonary parenchyma on magnetic resonance (MR) pulmonary perfusion imaging. Materials and Methods: Fifteen healthy volunteers underwent enhanced MR pulmonary perfusion imaging, to evaluate the effects of different injection rates. Injection rates were 1, 3, or 5 mL/second. Regions of interest (ROIs) were chosen in the lung and aorta to analyze the change in signal intensity over time. Results: As the injection rate increased, the peak enhancement occurred significantly earlier (P = 0.0012), but the peak enhancement signal-to-noise ratio (SNR) value was not affected (P = 0.25). With the 3- and 5-mL/second injection rates, images of both the pulmonary circulation and systemic circulation were obtained separately. However, with 1 mL/second, higher enhancement of the aorta was overlapped with peak enhancement of the lung tissue. Conclusion: The injection rate affects the enhancement profiles of the pulmonary parenchyma.
引用
收藏
页码:108 / 113
页数:6
相关论文
共 21 条
[1]  
Amundsen T, 2000, J Magn Reson Imaging, V12, P224, DOI 10.1002/1522-2586(200008)12:2<224::AID-JMRI3>3.0.CO
[2]  
2-E
[3]   Pulmonary embolism: Detection with MR perfusion imaging of lung - A feasibility study [J].
Amundsen, T ;
Kvaerness, J ;
Jones, RA ;
Waage, A ;
Bjermer, L ;
Nilsen, G ;
Haraldseth, O .
RADIOLOGY, 1997, 203 (01) :181-185
[4]   Lung perfusion demonstrated by contrast-enhanced dynamic magnetic resonance imaging - Application to unilateral lung transplantation [J].
Berthezene, Y ;
Croisille, P ;
Bertocchi, M ;
Houzard, C ;
Bendib, K ;
Revel, D .
INVESTIGATIVE RADIOLOGY, 1997, 32 (06) :351-356
[5]  
Berthezène Y, 1999, J MAGN RESON IMAGING, V9, P61, DOI 10.1002/(SICI)1522-2586(199901)9:1<61::AID-JMRI8>3.0.CO
[6]  
2-Z
[7]  
Bock M, 2000, MAGNET RESON MED, V43, P481, DOI 10.1002/(SICI)1522-2594(200003)43:3<481::AID-MRM21>3.0.CO
[8]  
2-N
[9]  
DEFFEBACH ME, 1987, AM REV RESPIR DIS, V135, P463
[10]   Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1996, 201 (03) :705-710