共 21 条
Effect of the rate of gadolinium injection on magnetic resonance pulmonary perfusion imaging
被引:21
作者:
Matsuoka, S
[1
]
Uchiyama, K
[1
]
Shima, H
[1
]
Terakoshi, H
[1
]
Oishi, S
[1
]
Nojiri, Y
[1
]
Ogata, H
[1
]
机构:
[1] Teikyo Univ, Sch Med, Ichihara Hosp, Dept Radiol, Chiba 2990111, Japan
关键词:
pulmonary;
lung perfusion;
magnetic resonance imaging (MRI);
contrast agent injection rate;
pulmonary circulation;
D O I:
10.1002/jmri.10038
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: To determine whether the injection rate of contrast agent affects the dynamics of enhancement of the pulmonary parenchyma on magnetic resonance (MR) pulmonary perfusion imaging. Materials and Methods: Fifteen healthy volunteers underwent enhanced MR pulmonary perfusion imaging, to evaluate the effects of different injection rates. Injection rates were 1, 3, or 5 mL/second. Regions of interest (ROIs) were chosen in the lung and aorta to analyze the change in signal intensity over time. Results: As the injection rate increased, the peak enhancement occurred significantly earlier (P = 0.0012), but the peak enhancement signal-to-noise ratio (SNR) value was not affected (P = 0.25). With the 3- and 5-mL/second injection rates, images of both the pulmonary circulation and systemic circulation were obtained separately. However, with 1 mL/second, higher enhancement of the aorta was overlapped with peak enhancement of the lung tissue. Conclusion: The injection rate affects the enhancement profiles of the pulmonary parenchyma.
引用
收藏
页码:108 / 113
页数:6
相关论文