Assessment of closed-loop ventilatory stability in obstructive sleep apnea

被引:32
作者
Asyali, MH
Berry, RB
Khoo, MCK
机构
[1] Univ So Calif, Dept Biomed Engn, Los Angeles, CA 90089 USA
[2] King Faisal Specialist Hosp & Res Ctr, Biostat Epidemiol & Sci Comp Dept, Riyadh 11211, Saudi Arabia
[3] Univ Florida, Dept Med, Gainesville, FL 32610 USA
关键词
minimal model; obstructive sleep apnea; respiratory control; stability;
D O I
10.1109/10.983454
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Previous studies on ventilatory control in obstructive sleep apnea (OSA) have generally indicated depressed chemosensitivity, implying greater stability of the chemical control of breathing in these subjects. However, these results were based on tests involving steady-state or quasi-steady measurements obtained in wakefulness. We have developed a method for assessing the dynamic stability characteristics of chemoreflex control in OSA patients during sleep. While continuous positive airway pressure was applied to stabilize the upper airways, acoustically stimulated arousals were used to perturb the respiratory system during sleep. The fluctuations in esophageal pressure that ensued were analyzed, using a closed-loop minimal model, to estimate the chemoreflex loop impulse response (CLIR). Tests using simulated data confirmed the validity of our estimation algorithm. Application of the method to arousal responses measured in six OSA and five normal subjects revealed no statistically significant differences in gain margins and loop gain magnitudes between the two groups. However, the CLIR in the OSA subjects exhibited faster and more oscillatory dynamics. This result implies that, in addition to unstable upper airway mechanics, an underdamped chemoreflex control system may be another important factor that promotes the occurrence of periodic obstructive apneas during sleep.
引用
收藏
页码:206 / 216
页数:11
相关论文
共 26 条
[11]   Instability of ventilatory control in patients with obstructive sleep apnea [J].
Hudgel, DW ;
Gordon, EA ;
Thanakitcharu, S ;
Bruce, EN .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (04) :1142-1149
[12]   Dynamics of periodic breathing and arousal during sleep at extreme altitude [J].
Khoo, MCK ;
Anholm, JD ;
Ko, SW ;
Downey, R ;
Powles, ACP ;
Sutton, JR ;
Houston, CS .
RESPIRATION PHYSIOLOGY, 1996, 103 (01) :33-43
[13]   Ventilatory dynamics during transient arousal from NREM sleep: Implications for respiratory control stability [J].
Khoo, MCK ;
Koh, SSW ;
Shin, JJW ;
Westbrook, PR ;
Berry, RB .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 80 (05) :1475-1484
[14]   Ventilatory dynamics of transient arousal in patients with obstructive sleep apnea [J].
Khoo, MCK ;
Shin, JJW ;
Asyali, MH ;
Kim, TS ;
Berry, RB .
RESPIRATION PHYSIOLOGY, 1998, 112 (03) :291-303
[15]  
KHOO MCK, 2000, PHYSL CONTROL SYSTEM, P189
[16]  
LOPATA M, 1982, AM REV RESPIR DIS, V126, P640
[17]   IDENTIFICATION OF NONLINEAR BIOLOGICAL-SYSTEMS USING LAGUERRE EXPANSIONS OF KERNELS [J].
MARMARELIS, VZ .
ANNALS OF BIOMEDICAL ENGINEERING, 1993, 21 (06) :573-589
[18]   INDICATIONS AND STANDARDS FOR CARDIOPULMONARY SLEEP STUDIES [J].
MARTIN, RJ ;
BLOCK, AJ ;
COHN, MA ;
CONWAY, WA ;
HUDGEL, DW ;
POWLES, ACP ;
SANDERS, MH ;
SMITH, PL .
SLEEP, 1985, 8 (04) :371-379
[19]  
ONAL E, 1982, AM REV RESPIR DIS, V126, P676
[20]  
Proakis JG., 1996, Digital signal processing, V3