Implants With Internal Hexagon and Conical Implant-Abutment Connections: An In Vitro Study of the Bacterial Contamination

被引:31
作者
D'Ercole, Simonetta [1 ]
Scarano, Antonio [1 ]
Perrotti, Vittoria [1 ]
Mulatinho, Jorge
Piattelli, Adriano [1 ]
Iezzi, Giovanna [1 ]
Tripodi, Domenico [1 ]
机构
[1] Univ G dAnnunzio, Sch Dent, Chieti, Italy
关键词
bacterial contamination; dental implants; implant-abutment connections; microbial leakage; MICROBIAL LEAKAGE; INTERFACE; COMPONENTS; SYSTEMS;
D O I
10.1563/AAID-JOI-D-11-00121
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
Prevention of microbial leakage at the implant-abutment junction is a major challenge for the construction of 2-stage implants in order to minimize inflammatory reactions and to maximize bone stability at the implant neck. The aim of the present in vitro study was an evaluation of the leakage observed over a period of 28 days in Cone Morse taper internal connections and in screwed-abutments connections. In the present study 10 specimens of Cone Morse (Group 1) and 10 of internal hexagon (Group 2) implants were used. The inner parts of 5 implants per group were inoculated with Pseudomonas aeruginosa (PS) suspension and 5 implants per group with Aggregatibacter actinomycetemcomitans (AA). The possible penetration of bacterial suspension into the surrounding solution was determined by the observation of turbidity of the broth. In Group 1, bacterial contamination was found in 3 out of 5 implant-abutment assemblies seeded with the PS and in 2 samples out of 5 in the assemblies seeded with AA, with a total of leaked assemblies in this group of 5 out of 10. In Group 2, bacterial contamination was found in 4 out of 5 implant-abutment assemblies seeded with the PS, and in 4 out of 5 samples seeded with AA, with a total of leaked assemblies of 8 out of 10. The present data confirm the reported high permeability to bacterial leakage of screw-retained abutment connections, and the lower infiltration rates-although not significantly-of Cone Morse taper internal connections.
引用
收藏
页码:31 / 36
页数:6
相关论文
共 17 条
[1]
Alcoforado G A, 1991, J Parodontol, V10, P11
[2]
Microbial leakage through the implant-abutment interface of morse taper implants in vitro [J].
Aloise, Joao Pedro ;
Curcio, Ricardo ;
Laporta, Marcia Zorello ;
Rossi, Liliane ;
Alvares da Silva, Adriana Madeira ;
Rapoport, Abrao .
CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (03) :328-335
[3]
Peri-implant inflammation defined by the implant-abutment interface [J].
Broggini, N ;
McManus, LM ;
Hermann, JS ;
Medina, R ;
Schenk, RK ;
Buser, D ;
Cochran, DL .
JOURNAL OF DENTAL RESEARCH, 2006, 85 (05) :473-478
[4]
In vitro evaluation of the implant abutment connection sealing capability of different implant systems [J].
Coelho, P. G. ;
Sudack, P. ;
Suzuki, M. ;
Kurtz, K. S. ;
Romanos, G. E. ;
Silva, N. R. F. A. .
JOURNAL OF ORAL REHABILITATION, 2008, 35 (12) :917-924
[5]
The Peri-Implant Sulcus Compared with Internal Implant and Suprastructure Components: A Microbiological Analysis [J].
Cosyn, Jan ;
Van Aelst, Louis ;
Collaert, Bruno ;
Persson, G. Rutger ;
De Bruyn, Hugo .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2011, 13 (04) :286-295
[6]
Dibart S, 2005, INT J ORAL MAX IMPL, V20, P732
[7]
Bacterial leakage along the implant-abutment interface of premachined or cast components [J].
do Nascimento, C. ;
Barbosa, R. E. S. ;
Issa, J. P. M. ;
Watanabe, E. ;
Ito, I. Y. ;
Junior, R. F. Albuquerque .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 37 (02) :177-180
[8]
Influence of repeated screw tightening on bacterial leakage along the implant-abutment interface [J].
do Nascimento, Cassio ;
Pedrazzi, Vinicius ;
Miani, Paola Kirsten ;
Moreira, Larissa Daher ;
de Albuquerque Junior, Rubens Ferreira .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (12) :1394-1397
[9]
Molecular leakage at implant-abutment connection-in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration [J].
Harder, Soenke ;
Dimaczek, Birka ;
Acil, Yaha ;
Terheyden, Hendrik ;
Freitag-Wolf, Sandra ;
Kern, Matthias .
CLINICAL ORAL INVESTIGATIONS, 2010, 14 (04) :427-432
[10]
Biologic Width around one- and two-piece titanium implants - A histometric evaluation of unloaded nonsubmerged and submerged implants in the canine mandible [J].
Hermann, JS ;
Buser, D ;
Schenk, RK ;
Schoolfield, JD ;
Cochran, DL .
CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (06) :559-571