Capillary array electrophoresis-MALDI mass spectrometry using a vacuum deposition interface

被引:78
作者
Preisler, J [1 ]
Hu, P
Rejtar, T
Moskovets, E
Karger, BL
机构
[1] Northeastern Univ, Barnett Inst, Boston, MA 02115 USA
[2] Northeastern Univ, Dept Chem, Boston, MA 02115 USA
关键词
D O I
10.1021/ac010692p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We previously introduced a vacuum deposition interface for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI/TOF MS) on a moving surface (e.g., quartz wheel, Mylar tape, metal target). In our present work, the approach has been extended to demonstrate parallel analysis for multiple on-line infusion MALDI MS and capillary array electrophoresis (CAE)-MALDI MS. In the infusion mode, individual peptide samples were simultaneously deposited on a Mylar tape cartridge using an array of eight capillaries, yielding eight parallel traces. For CAE-MALDI/TOF MS, the same number of separation capillaries were coupled with an array of eight infusion capillaries using a common liquid junction, containing matrix solution. A fast-scanning mirror was employed to traverse the beam of the desorption laser across the Mylar tape to probe one trace at a time. The positions of the eight sample traces formed on the tape were automatically determined, and all samples were anal,zed in rapid sequence using a kilohertz; repetition rate laser and a high-throughput data acquisition system. The instrumentation was operated with CAE MS for high-throughput analysis without compromising data quality. The principles of parallel separation-vacuum deposition should be generally applicable to MALDI/TOF MS analysis for proteomics and other areas where separation and high throughput are required.
引用
收藏
页码:17 / 25
页数:9
相关论文
共 52 条
  • [11] Signature-peptide approach to detecting proteins in complex mixtures
    Geng, MH
    Ji, JY
    Regnier, FE
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 870 (1-2) : 295 - 313
  • [12] Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
    Gygi, SP
    Rist, B
    Gerber, SA
    Turecek, F
    Gelb, MH
    Aebersold, R
    [J]. NATURE BIOTECHNOLOGY, 1999, 17 (10) : 994 - 999
  • [13] CONTINUOUS-FLOW MALDI MASS-SPECTROMETRY USING AN ION-TRAP REFLECTION TIME-OF-FLIGHT DETECTOR
    HE, L
    LIANG, L
    LUBMAN, DM
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (22) : 4127 - 4132
  • [14] Hensel RR, 1997, RAPID COMMUN MASS SP, V11, P1785
  • [15] ATTOMOLE DETECTION OF PROTEINS BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION MASS-SPECTROMETRY WITH THE USE OF PICOLITRE VIALS
    JESPERSEN, S
    NIESSEN, WMA
    TJADEN, UR
    VANDERGREEF, J
    LITBORN, E
    LINDBERG, U
    ROERAADE, J
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (08) : 581 - 584
  • [16] Karger B. L., 1998, United States patent, Patent No. [US 5840388, 5840388]
  • [17] EFFECT OF MULTIPLE SPRAYERS ON DYNAMIC-RANGE AND FLOW-RATE LIMITATIONS IN ELECTROSPRAY AND IONSPRAY MASS-SPECTROMETRY
    KOSTIAINEN, R
    BRUINS, AP
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (07) : 549 - 558
  • [18] Rapidly switchable matrix-assisted laser desorption/ionization and electrospray quadrupole-time-of-flight mass spectrometry for protein identification
    Krutchinsky, AN
    Zhang, WZ
    Chait, BT
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (06) : 493 - 504
  • [19] High-throughput characterization of combinatorial libraries generated by parallel synthesis
    Kyranos, JN
    Hogan, JC
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (11) : 389A - 395A
  • [20] Lahm HW, 2000, ELECTROPHORESIS, V21, P2105, DOI 10.1002/1522-2683(20000601)21:11<2105::AID-ELPS2105>3.0.CO