An amperometric biosensor for xanthine determination prepared from xanthine oxidase immobilized in polypyrrole film

被引:39
作者
Arslan, F [1 ]
Yasar, A
Kiliç, E
机构
[1] Gazi Univ, Fac Arts & Sci, Dept Chem, Ankara, Turkey
[2] Ankara Univ, Fac Sci, Dept Chem, TR-06100 Ankara, Turkey
来源
ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY | 2006年 / 34卷 / 01期
关键词
xanthine biosensor; amperometry; polypyrrole; ferrocene;
D O I
10.1080/10731190500430289
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In order to prepare a biosensor for the determination of xanthine, electropolymerization of pyrrole on Pt surface was carried out with an electrochemical cell containing pyrrole, ferrocene (as a electron mediator) and tetrabutylamonium tetrafluoroborat in acetonitrile by cyclic voltammetry between 0.0 and 0.9 V (vs SCE) at a scan rate of 50 mV/s upon Pt electrode. Xanthine oxidase was immobilized by a glutaraldehyde/bovine serum albumin (BSA) crosslinking procedure on to polypyrrole film after the electropolymerization processes. The response of the biosensor against xanthine was measured after 3-4 min following the application of a constant potential of +0.7 V (vs SCE). The resulting biosensor exhibits excellent electrocatalysis for the xanthine. The amperometric determination is based on the electrochemical detection of H2O2 , which is generated in enzymatic reaction of xanthine. The effect of various experimental conditions was examined for the determination of the analytical performance. The sensor responds to xanthine with a detection limit of 1.0 x 10(-6) M. The response current increases linearly with xanthine concentration up to 4.0 x 10(-4) M. The sensor remains relatively stable for 45 days.
引用
收藏
页码:113 / 128
页数:16
相关论文
共 22 条
  • [1] Polypyrrole-based amperometric flow injection biosensor for urea
    Adeloju, SB
    Shaw, SJ
    Wallace, GG
    [J]. ANALYTICA CHIMICA ACTA, 1996, 323 (1-3) : 107 - 113
  • [2] Xanthine and hypoxanthine sensors based on xanthine oxidase immobilized in poly(mercapto-p-benzoquinone) film
    Arai, G
    Takahashi, S
    Yasumori, I
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 410 (02): : 173 - 179
  • [3] Development of a bienzymic graphite-Teflon composite electrode for the determination of hypoxanthine in fish
    Cayuela, G
    Peña, N
    Reviejo, AJ
    Pingarrón, JM
    [J]. ANALYST, 1998, 123 (02) : 371 - 377
  • [4] Mediated biosensors
    Chaubey, A
    Malhotra, BD
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) : 441 - 456
  • [5] Chaubey A, 2000, ELECTROCHIM ACTA, V46, P723
  • [6] Application of conducting polymers to biosensors
    Gerard, M
    Chaubey, A
    Malhotra, BD
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (05) : 345 - 359
  • [7] Gros P, 2000, ELECTROCHIM ACTA, V46, P643
  • [8] AMPEROMETRIC ENZYME ELECTRODE FOR AEROBIC GLUCOSE MONITORING PREPARED BY GLUCOSE-OXIDASE IMMOBILIZED IN POLY(VINYLFERROCENIUM)
    GULCE, H
    OZYORUK, H
    CELEBI, SS
    YILDIZ, A
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 394 (1-2): : 63 - 70
  • [9] IL-10 deficiency increases superoxide and endothelial dysfunction during inflammation
    Gunnett, CA
    Heistad, DD
    Berg, DJ
    Faraci, FM
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2000, 279 (04): : H1555 - H1562
  • [10] FIBEROPTIC BIOSENSOR FOR HYPOXANTHINE AND XANTHINE BASED ON A CHEMILUMINESCENCE REACTION
    HLAVAY, J
    HAEMMERLI, SD
    GUILBAULT, GG
    [J]. BIOSENSORS & BIOELECTRONICS, 1994, 9 (03) : 189 - 195