Magnetic susceptibility effects on the accuracy of MR temperature monitoring by the proton resonance frequency method

被引:29
作者
Boss, A
Graf, H
Müller-Bierl, B
Clasen, S
Schmidt, D
Pereira, PL
Schick, F
机构
[1] Univ Tubingen, Sect Expt Radiol, D-72076 Tubingen, Germany
[2] Univ Tubingen, Dept Diagnost Radiol, D-72076 Tubingen, Germany
关键词
susceptibility effects; proton resonance frequency method; radiofrequency ablation; thermometry; ablation monitoring;
D O I
10.1002/jmri.20438
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the error of MR temperature assessment based on the temperature-dependent Larmor frequency shift of water protons. which can result from susceptibility effects caused by the radiofrequency (RF) applicator. Materials and Methods: Local frequency shifts clue to RF applicator displacements were simulated numerically by means of a three-dimensional elementary dipole model. Experimental examinations using a water tank phantom equipped with a high-precision screw thread were applied to examine temperature and movement effects for five commercially available, MR-compatible RF applicators. Measurements were performed at 1.5 Tesla. Results: For single-needle electrodes perpendicular to the external field, a distortion of 0.1 ppm and 0.2 ppm was recorded at a distance of 17.5 mm and 12.5 mm, respectively, to the needle shaft. Cluster applicators and umbrella-shaped applicators caused distortions of 0.1 ppm up to distances of 36 mm. Sinusoidal dependence on applicator orientation was found with the highest values for perpendicular orientation and the lowest values for orientation parallel to the magnetic field. With a single electrode oriented perpendicular to the field at a distance of 1.5 cm and 2.0 cm, a needle displacement of 5 min led to an error in temperature measurement of 16.3 degrees C and 7.5 degrees C, respectively. Conclusion: In MR temperature measurement, displacement of the RF applicator by patient movement or breathing leads to significant errors that have to be taken into account when PRF temperature maps are used to monitor tumor ablation in the presence of paramagnetic applicators.
引用
收藏
页码:813 / 820
页数:8
相关论文
共 22 条
[1]   Temperature quantification using the proton frequency shift technique: In vitro and in vivo validation in an open 0.5 tesla interventional MR scanner during RF ablation [J].
Botnar, RM ;
Steiner, P ;
Dubno, B ;
Erhart, P ;
von Schulthess, GK ;
Debatin, JF .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (03) :437-444
[2]  
DEPOORTER J, 1995, MAGN RESON MED, V34, P359, DOI 10.1002/mrm.1910340313
[3]  
DEPOORTER J, 1995, MAGNET RESON MED, V33, P74, DOI 10.1002/mrm.1910330111
[4]   Percutaneous radiofrequency tissue ablation: Optimization of pulsed radiofrequency technique to increase coagulation necrosis [J].
Goldberg, SN ;
Stein, MC ;
Gazelle, GS ;
Sheiman, RG ;
Kruskal, JB ;
Clouse, ME .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (07) :907-916
[5]  
Goldberg SN, 2001, HEPATO-GASTROENTEROL, V48, P359
[6]  
HAACKE EM, 1999, MAGNETIC RESONANCE I, P752
[7]   MAPPING OF PH AND TEMPERATURE DISTRIBUTION USING CHEMICAL-SHIFT-RESOLVED TOMOGRAPHY [J].
HALL, LD ;
TALAGALA, SL .
JOURNAL OF MAGNETIC RESONANCE, 1985, 65 (03) :501-505
[8]   PROTON RESONANCE SHIFT OF WATER IN GAS AND LIQUID STATES [J].
HINDMAN, JC .
JOURNAL OF CHEMICAL PHYSICS, 1966, 44 (12) :4582-&
[9]  
Huber PE, 2001, CANCER RES, V61, P8441
[10]   PRECISE AND FAST TEMPERATURE MAPPING USING WATER PROTON CHEMICAL-SHIFT [J].
ISHIHARA, Y ;
CALDERON, A ;
WATANABE, H ;
OKAMOTO, K ;
SUZUKI, Y ;
KURODA, K ;
SUZUKI, Y .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) :814-823