In vivo validation of a new technique that compensates for soft tissue artefact in the upper-arm: Preliminary results

被引:35
作者
Cutti, AG
Cappello, A
Davalli, A
机构
[1] Univ Bologna, Dept Elect Comp Sci & Syst, I-40136 Bologna, Italy
[2] INAIL Prosthesis Ctr, I-40054 Vigorso di Budrio, Italy
关键词
movement analysis; axial rotation; humerus; soft tissue artefact; stereophotogrammetry; calibrated anatomical system technique;
D O I
10.1016/j.clinbiomech.2005.09.018
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. Soft tissue artefact is the dominant error source for upper extremity motion analyses that use skin-mounted markers, especially in humeral axial rotation. Methods. A new in vivo technique is presented that is based on the definition of a humerus bone-embedded frame almost "artefact free" but influenced by the elbow orientation in the measurement of the humeral axial rotation, and on an algorithm designed to solve this kinematic coupling. The technique was validated in vivo in a study of six healthy subjects who performed five arm-movement tasks. For each task the similarity between a gold standard pattern and the axial rotation pattern before and after the application of the compensation algorithm was evaluated in terms of explained variance, gain, phase and offset. In addition the root mean square error between the patterns was used as a global similarity estimator. Findings. After the application, for four out of five tasks, patterns were highly correlated, in phase, with almost equal gain and limited offset; the root mean square error decreased from the original 9 degrees to 3 degrees. Interpretation. The proposed technique appears to help compensate for the soft tissue artefact affecting axial rotation. A further development is also proposed to make the technique effective also for the pure prono-supination task. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S13 / S19
页数:7
相关论文
共 14 条
[1]   Kinematics of human arm reconstructed from spatial tracking system recordings [J].
Biryukova, EV ;
Roby-Brami, A ;
Frolov, AA ;
Mokhtari, M .
JOURNAL OF BIOMECHANICS, 2000, 33 (08) :985-995
[2]  
Buckley M A, 1996, Proc Inst Mech Eng H, V210, P241, DOI 10.1243/PIME_PROC_1996_210_420_02
[3]  
CAPPELLO A, 2005, IEEE T BIOMED ENG, V52
[4]   Soft tissue artefact assessment in humeral axial rotation [J].
Cutti, AG ;
Paolini, G ;
Troncossi, M ;
Cappello, A ;
Davalli, A .
GAIT & POSTURE, 2005, 21 (03) :341-349
[5]   A NEW TECHNIQUE FOR COMPENSATING THE SOFT TISSUE ARTEFACT AT THE UPPER-ARM: IN VITRO VALIDATION [J].
Cutti, Andrea Giovanni ;
Cappello, Angelo ;
Davalli, Angelo .
JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2005, 5 (02) :333-347
[6]   Skin movement artefact assessment and compensation in the estimation of knee-joint kinematics [J].
Lucchetti, L ;
Cappozzo, A ;
Cappello, A ;
Della Croce, U .
JOURNAL OF BIOMECHANICS, 1998, 31 (11) :977-984
[7]  
Petruccelli J. D., 1999, APPL STAT ENG SCI
[8]   Evaluation of the global optimisation method within the upper limb kinematics analysis [J].
Roux, E ;
Bouilland, S ;
Godillon-Maquinghen, AP ;
Bouttens, D .
JOURNAL OF BIOMECHANICS, 2002, 35 (09) :1279-1283
[9]   A marker-based measurement procedure for unconstrained wrist and elbow motions [J].
Schmidt, R ;
Disselhorst-Klug, C ;
Silny, J ;
Rau, G .
JOURNAL OF BIOMECHANICS, 1999, 32 (06) :615-621
[10]   Parameters for modeling the upper extremity [J].
Veeger, HEJ ;
Yu, B ;
An, KN ;
Rozendal, RH .
JOURNAL OF BIOMECHANICS, 1997, 30 (06) :647-652