Isotopic pattern and accurate mass determination in urine drug screening by liquid chromatography/time-of-flight mass spectrometry

被引:175
作者
Ojanperä, S
Pelander, A
Pelzing, M
Krebs, I
Vuori, E
Ojanperä, I
机构
[1] Univ Helsinki, Dept Forens Med, FI-00014 Helsinki, Finland
[2] Bruker Daltonik GmbH, D-28355 Bremen, Germany
关键词
D O I
10.1002/rcm.2429
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An efficient method was developed for toxicological drug screening in urine by liquid chromatography coupled with electrospray ionization time-of-flight mass spectrometry. The method relies on a large target database of exact monoisotopic masses representing the elemental formulae of reference drugs and their metabolites. Mass spectral identification is based on matching measured accurate mass and isotopic pattern (SigmaFit (TM)) of a sample component with those in the database. Data post-processing software was developed for automated reporting of findings in an easily interpretable form. The mean and median of SigmaFit (TM) for true-positive findings were 0.0066 and 0.0051, respectively. The mean and median of mass error absolute values for true-positive findings were 2.51 and 2.17ppm, respectively, corresponding to 0.65 and 0.60mTh. For routine screening practice, a SigmaFit (TM) tolerance of 0.03 and a mass tolerance of 10 ppm were chosen. Ion abundance differences from urine extracts did not affect the accuracy of the automatically acquired SigmaFit (TM) or mass values. The results show that isotopic pattern matching by SigmaFitTm is a powerful means of identification in addition to accurate mass measurement. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:1161 / 1167
页数:7
相关论文
共 26 条
[1]   Determination of organic acids in aerosol particles from a coniferous forest by liquid chromatography-mass spectrometry [J].
Anttila, P ;
Hyötyläinen, T ;
Heikkilä, A ;
Jussila, M ;
Finell, J ;
Kulmala, M ;
Riekkola, ML .
JOURNAL OF SEPARATION SCIENCE, 2005, 28 (04) :337-346
[2]  
CHERNUSHEVICH IV, 1997, ELECTROSPRAY IONIZAT, P203
[3]   Accurate mass liquid chromatography/mass spectrometry on orthogonal acceleration time-of-flight mass analyzers using switching between separate sample and reference sprays. 1. Proof of concept [J].
Eckers, C ;
Wolff, JC ;
Haskins, NJ ;
Sage, AB ;
Giles, K ;
Bateman, R .
ANALYTICAL CHEMISTRY, 2000, 72 (16) :3683-3688
[4]   Parallel high-throughput accurate mass measurement using a nine-channel multiplexed electrospray liquid chromatography ultraviolet time-of-flight mass spectrometry system [J].
Fang, LL ;
Demee, M ;
Cournoyer, J ;
Sierra, T ;
Young, C ;
Yan, B .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (13) :1425-1432
[5]   Toxicological screening of urine for drugs by liquid chromatography/time-of-flight mass spectrometry with automated target library search based on elemental formulas [J].
Gergov, M ;
Boucher, B ;
Ojanperä, I ;
Vuori, E .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (08) :521-526
[6]  
Guilhaus M, 1997, RAPID COMMUN MASS SP, V11, P951
[7]   Use of quadrupole time-of-flight mass spectrometry in the elucidation of unknown compounds present in environmental water [J].
Ibáñez, M ;
Sancho, JV ;
Pozo, OJ ;
Niessen, W ;
Hernández, F .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (02) :169-178
[8]  
*INT SORB TECHN, 1997, SPE APPL NOT EXTR AC
[9]   PROGRAM FOR ELEMENTAL ANALYSIS USING LOW OR MEDIUM RESOLUTION MASS-SPECTRA [J].
KAVANAGH, PE .
ORGANIC MASS SPECTROMETRY, 1980, 15 (07) :334-335
[10]   Analysis of street drugs in seized material without primary reference standards [J].
Laks, S ;
Pelander, A ;
Vuori, E ;
Ali-Tolppa, E ;
Sippola, E ;
Ojanperä, I .
ANALYTICAL CHEMISTRY, 2004, 76 (24) :7375-7379