Production of highly purified clotting factor IX by a combination of different chromatographic methods

被引:29
作者
Hoffer, L [1 ]
Schwinn, H [1 ]
Josic, D [1 ]
机构
[1] Octapharma Pharmazeut Prod Ges MbH, A-1100 Vienna, Austria
关键词
factor IX; glycoproteins; proteins;
D O I
10.1016/S0021-9673(99)00348-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly enriched preparation of human clotting factor IX was produced by a combination of adsorption chromatography, hydrophobic interaction chromatography and heparin affinity chromatography. The introduction of adsorption chromatography with a hydroxyaminopropyl support allows the capture step to be carried out directly from the cryoprecipitate-depleted plasma with a chromatographic column in flow-through mode. This replaces the batch procedure used until now. The other two chromatographic steps are designed in such a way that the eluate from the preceding step can be directly applied, without any intermediate treatment of the sample. This cuts the period of time required for the process by almost 50%, and increases the yield considerably. The isolated factor IX contains practically no contaminants and has a specific activity over 200 IU/mg of protein. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:119 / 128
页数:10
相关论文
共 26 条
[1]   FACTOR-IX CONCENTRATE VERSUS PROTHROMBIN COMPLEX CONCENTRATE FOR THE TREATMENT OF HEMOPHILIA-B DURING SURGERY [J].
BARDIN, JM ;
SULTAN, Y .
TRANSFUSION, 1990, 30 (05) :441-443
[2]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[3]  
BRUMMELHUIS HGJ, 1980, METHODS PLASMA PROTE, P117
[4]   High-performance capillary electrophoresis for in-process control in the production of antithrombin III and human clotting factor IX [J].
Buchacher, A ;
Schulz, P ;
Choromanski, J ;
Schwinn, H ;
Josic, D .
JOURNAL OF CHROMATOGRAPHY A, 1998, 802 (02) :355-366
[5]   PROPERTIES OF A HIGHLY PURIFIED HUMAN-PLASMA FACTOR-IX-C THERAPEUTIC CONCENTRATE PREPARED BY CONVENTIONAL CHROMATOGRAPHY [J].
BURNOUF, T ;
MICHALSKI, C ;
GOUDEMAND, M ;
HUART, JJ .
VOX SANGUINIS, 1989, 57 (04) :225-232
[6]  
Burnouf T., 1991, BIOSEPARATION, P383
[7]   NANOFILTRATION, A NEW SPECIFIC VIRUS ELIMINATION METHOD APPLIED TO HIGH-PURITY FACTOR-IX AND FACTOR-XI CONCENTRATES [J].
BURNOUFRADOSEVICH, M ;
APPOURCHAUX, P ;
HUART, JJ ;
BURNOUF, T .
VOX SANGUINIS, 1994, 67 (02) :132-138
[8]  
Davie EW, 1991, BIOCHEMISTRY-US, V30, P10364
[9]   HIGH-RESOLUTION REMOVAL OF VIRUS FROM PROTEIN SOLUTIONS USING A MEMBRANE OF UNIQUE STRUCTURE [J].
DILEO, AJ ;
ALLEGREZZA, AE ;
BUILDER, SE .
BIO-TECHNOLOGY, 1992, 10 (02) :182-188
[10]  
DISCIPIO RG, 1977, BIOCHEMISTRY-US, V16, P698, DOI 10.1021/bi00623a022