An evaluation of epoxy resin phantom materials for megavoltage photon dosimetry

被引:27
作者
Allahverdi, M [1 ]
Nisbet, A [1 ]
Thwaites, DI [1 ]
机构
[1] Univ Edinburgh, Western Gen Hosp, Dept Med Phys & Med Engn, Edinburgh EH4 2XU, Midlothian, Scotland
关键词
D O I
10.1088/0031-9155/44/5/001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Epoxy resin phantom materials have been available for some time and are widely used for dosimetry purposes, not least in audit phantoms. Information on their behaviour is partly available in the literature, but there are different mixes and formulations often given similar names and it may not be appropriate to transfer information from one material to another. Five commercially available water-substitute materials have been evaluated for use in megavoltage photon beams: WT1, WTe, RMI 451, RMI 457 and 'plastic water'. Four independent experiments were carried out to compare these materials with water in megavoltage photon beams ranging in energy from cobalt-60 to nominal 16 MV x-rays, and some general conclusions are drawn from the results as to their use. All are suitable for relative dosimetry in megavoltage photon beams. However, differences of up to 1% are observed for absolute measurements. The newer formulations, developed for electron beam use, are also closer to water for megavoltage photon beams.
引用
收藏
页码:1125 / 1132
页数:8
相关论文
共 11 条
[1]  
ALLAHVERDI M, 1999, UNPUB PHYS MED BIOL
[2]   White polystyrene as a substitute for water in high energy photon dosimetry [J].
Christ, G .
MEDICAL PHYSICS, 1995, 22 (12) :2097-2100
[3]   A SOLID WATER PHANTOM MATERIAL FOR RADIOTHERAPY X-RAY AND GAMMA-RAY BEAM CALIBRATIONS [J].
CONSTANTINOU, C ;
ATTIX, FH ;
PALIWAL, BR .
MEDICAL PHYSICS, 1982, 9 (03) :436-441
[4]  
CONSTANTINOU C, 1978, THESIS LONDON U
[5]  
Goldstone KE, 1990, 44 ICRU
[6]   STOPPING-POWER AND MASS ENERGY-ABSORPTION COEFFICIENT RATIOS FOR SOLID WATER [J].
HO, AK ;
PALIWAL, BR .
MEDICAL PHYSICS, 1986, 13 (03) :403-404
[7]   CODE OF PRACTICE FOR HIGH-ENERGY PHOTON THERAPY DOSIMETRY BASED ON THE NPL ABSORBED DOSE CALIBRATION SERVICE [J].
LILLICRAP, SC ;
OWEN, B ;
WILLIAMS, JR ;
WILLIAMS, PC .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (10) :1355-1360
[8]   A dosimetric intercomparison of electron beams in UK radiotherapy centres [J].
Nisbet, A ;
Thwaites, DI .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (12) :2393-2409
[9]   HOW WATER EQUIVALENT ARE WATER-EQUIVALENT SOLID MATERIALS FOR OUTPUT CALIBRATION OF PHOTON AND ELECTRON-BEAMS [J].
TELLO, VM ;
TAILOR, RC ;
HANSON, WF .
MEDICAL PHYSICS, 1995, 22 (07) :1177-1189
[10]   A DOSIMETRIC INTERCOMPARISON OF MEGAVOLTAGE PHOTON BEAMS IN UK RADIOTHERAPY CENTERS [J].
THWAITES, DI ;
WILLIAMS, JR ;
AIRD, EG ;
KLEVENHAGEN, SC ;
WILLIAMS, PC .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (02) :445-461