Reversible cyclic voltammetry of the NADH/NAD+ redox system on hybrid poly(luminol)/FAD film modified electrodes

被引:70
作者
Lin, KC [1 ]
Chen, SM [1 ]
机构
[1] Natl Taipei Univ Technol, Dept Chem Engn & Biotechnol, Taipei 106, Taiwan
关键词
luminol; FAD; film modified electrodes; electrocatalysis; NADH;
D O I
10.1016/j.jelechem.2006.01.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hybrid films composed of electropolymerized luminol-flavin adenine dinucleotide (FAD) adsorbed film modified electrodes have been prepared in aqueous acidic solutions. These films are stable and electrochemically active, and can be produced on glassy carbon, platinum, gold, and transparent semiconductor tin oxide electrodes. The hybrid poly(luminol)/FAD film showed two redox couples. Electrochemical quartz crystal microbalance and cyclic voltammetry were used to study the in situ growth of hybrid poly(luminol)/FAD and poly(luminol) films. The modified electrode was transferred into various aqueous acidic solutions, the two redox couples and the formal potentials of the hybrid films were observed to be pH-dependent. The electrocatalytic oxidation and reduction of NADH and NAD(+) by a polyluminol/FAD hybrid film in aqueous solutions with various pH were carried out. The electrocatalytic oxidation of NADH and the reversible electrocatalytic reactions of NADH/NAD(+) using a poly(luminol)/FAD hybrid film were found to be active. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:52 / 59
页数:8
相关论文
共 48 条
[21]   ELECTROCHEMISTRY OF POLYNUCLEAR TRANSITION-METAL CYANIDES - PRUSSIAN BLUE AND ITS ANALOGS [J].
ITAYA, K ;
UCHIDA, I ;
NEFF, VD .
ACCOUNTS OF CHEMICAL RESEARCH, 1986, 19 (06) :162-168
[22]   Peroxidase-catalysed luminol chemiluminescence method for the determination of glutathione [J].
Kamidate, T ;
Watanabe, H .
TALANTA, 1996, 43 (10) :1733-1738
[23]   Electrochemical detection in bioanalysis [J].
Kissinger, PT .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (8-10) :871-880
[24]   CYCLIC VOLTAMMETRY STUDIES OF COPPER AND NICKEL HEXACYANOFERRATE IMMOBILIZED ON A SILICA-GEL SURFACE-COATED WITH TITANIUM(IV) OXIDE [J].
KUBOTA, LT ;
GUSHIKEM, Y .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 362 (1-2) :219-225
[25]   APPLICATION OF CHELATE-FORMING RESIN AND MODIFIED GLASSY-CARBON ELECTRODE FOR SELECTIVE DETERMINATION OF IRON(III) BY LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
KULESZA, PJ ;
BRAJTER, K ;
DABEKZLOTORZYNSKA, E .
ANALYTICAL CHEMISTRY, 1987, 59 (23) :2776-2780
[26]   Electrochemiluminescent labels for applications in fully aqueous solutions at oxide-covered aluminium electrodes [J].
Kulmala, S ;
Helin, M ;
Ala-Kleme, T ;
Väre, L ;
Papkovsky, D ;
Korpela, T ;
Kulmala, A .
ANALYTICA CHIMICA ACTA, 1999, 386 (1-2) :1-6
[27]   CATALYTIC ELECTROOXIDATION OF HYDRAZINE AT THE NICKEL FERRICYANIDE MODIFIED ELECTRODE - CAN AN ARRAY OF SURFACE BOUND ONE-ELECTRON REDOX CENTERS ACT IN CONCERT [J].
LIN, C ;
BOCARSLY, AB .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 300 (1-2) :325-345
[28]   A simple chemiluminescence assay for the determination of reactive oxygen species produced by human neutrophils [J].
Liu, L ;
Dahlgren, C ;
Elwing, H ;
Lundqvist, H .
JOURNAL OF IMMUNOLOGICAL METHODS, 1996, 192 (1-2) :173-178
[29]   CHARACTERIZATION OF GLUCOSE OXIDASE-MODIFIED POLY(PHENYLENEDIAMINE)-COATED ELECTRODES IN-VITRO AND IN-VIVO - HOMOGENEOUS INTERFERENCE BY ASCORBIC-ACID IN HYDROGEN-PEROXIDE DETECTION [J].
LOWRY, JP ;
MCATEER, K ;
ELATRASH, SS ;
DUFF, A ;
ONEILL, RD .
ANALYTICAL CHEMISTRY, 1994, 66 (10) :1754-1761
[30]   Synthesis and spectroscopic properties of new luminol-linked calixarene derivatives [J].
Ma, HM ;
Jarzak, U ;
Thiemann, W .
ANALYTICA CHIMICA ACTA, 1998, 362 (2-3) :121-129