Prediction of cardiac stability after weaning from left ventricular assist devices in patients with idiopathic dilated cardiomyopathy

被引:125
作者
Dandel, Michael [1 ]
Weng, Yuguo [1 ]
Siniawski, Henryk [1 ]
Potapov, Evgenij [1 ]
Drews, Thorsten [1 ]
Lehmkuhl, Hans B. [1 ]
Knosalla, Christoph [1 ]
Hetzer, Roland [1 ]
机构
[1] Deutsch Herzzentrum Berlin, Dept Cardiothorac & Vasc Surg, D-13353 Berlin, Germany
关键词
cardiomyopathy; echocardiography; heart failure; outcome; ventricular assist device;
D O I
10.1161/CIRCULATIONAHA.107.755983
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-During ventricular assist device (VAD) unloading, cardiac recovery is possible even in patients with chronic heart failure (HF). We sought parameters predictive of cardiac stability after VAD removal. Methods and Results-Among 81 patients weaned since March 1995, a homogenous group of 35 with idiopathic dilated cardiomyopathy weaned from left VADs was selected. We evaluated echo data obtained before left VAD implantation and during "off-pump" trials before explantation, histological changes, and serum anti-beta 1-adrenoceptor-autoantibody disappearance during unloading, duration of unloading, and HF duration. Postweaning 10-year survival with native hearts reached 70.7 +/- 9.2%. During the first 5 years, HF recurred in 13 patients (37.1%). Only 6 (17.1%) died after HF recurrence or noncardiac complications related to left VAD explantation. Comparison of patients with and without long-term cardiac stability showed that stable patients were younger, HF history and recovery time during unloading shorter, and preweaning left ventricular assessment revealed higher left ventricular ejection fraction, lower short/long axis ratios, and higher end diastolic relative wall thicknesses. For left ventricular ejection fraction >= 45% at end diastolic diameter of <= 55 mm, predictive value for >= 5-year cardiac stability was 87.5%. Left ventricular ejection fraction time course during the first 6 postweaning months appeared predictive for long-term stability. HF history >5 years and preweaning instability of cardiac improvement appeared predictive for HF recurrence. Conclusions-In idiopathic dilated cardiomyopathy, left VAD removal can be successful for >12 years even with incomplete cardiac recovery. Pre-explantation left ventricular ejection fraction, left ventricular end diastolic diameter and relative wall thicknesses, stability of unloading-induced cardiac recovery, duration of left VAD support, and HF duration before left VAD insertion allow identification of patients able to remain stable for >5 years. Time course of left ventricular ejection fraction during the first 6 postweaning months allows prognostic assessment.
引用
收藏
页码:S94 / S105
页数:12
相关论文
共 21 条
[1]  
Aurigemma G., 2002, PRACTICE CLIN ECHOCA, P65
[2]   Left ventricular assist device and drug therapy for the reversal of heart failure [J].
Birks, Emma J. ;
Tansley, Patrick D. ;
Hardy, James ;
George, Robert S. ;
Bowles, Christopher T. ;
Burke, Margaret ;
Banner, Nicholas R. ;
Khaghani, Asghar ;
Yacoub, Magdi H. .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (18) :1873-1884
[3]   Long-term results in patients with idiopathic dilated cardiomyopathy after weaning from left ventricular assist devices [J].
Dandel, M ;
Weng, YG ;
Siniawski, H ;
Potapov, E ;
Lehmkuhl, HB ;
Hetzer, R .
CIRCULATION, 2005, 112 (09) :I37-I45
[4]  
Dandel M, 2001, CIRCULATION, V104, pI184
[5]   Mechanical Circulatory Support device database of the International Society for Heart and Lung Transplantation: Second Annual Report-2004 [J].
Deng, MC ;
Edwards, LB ;
Hertz, MI ;
Rowe, AW ;
Keck, BM ;
Kormos, R ;
Naftel, DC ;
Kirklin, JK .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2004, 23 (09) :1027-1034
[6]   Long-term follow-up of thoratec ventricular assist device bridge-to-recovery patients successfully removed from support after recovery of ventricular function [J].
Farrar, DJ ;
Holman, WR ;
McBride, LR ;
Kormos, RL ;
Icenogle, TB ;
Hendry, PJ ;
Moore, CH ;
Loisance, DY ;
El-Banayosy, A ;
Frazier, H .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2002, 21 (05) :516-521
[7]  
Frazier O H, 2004, Congest Heart Fail, V10, P109, DOI 10.1111/j.1527-5299.2004.03366.x
[8]   Improved left ventricular function after chronic left ventricular unloading [J].
Frazier, OH ;
Benedict, CR ;
Radovancevic, B ;
Bick, RJ ;
Capek, P ;
Springer, WE ;
Macris, MP ;
Delgado, R ;
Buja, LM .
ANNALS OF THORACIC SURGERY, 1996, 62 (03) :675-681
[9]   Left ventricular assist system as a bridge to myocardial recovery [J].
Frazier, OH ;
Myers, TJ .
ANNALS OF THORACIC SURGERY, 1999, 68 (02) :734-741
[10]   Cardiac recovery in dilated cardiomyopathy by unloading with a left ventricular assist device [J].
Hetzer, R ;
Müller, J ;
Weng, YG ;
Wallukat, G ;
Spiegelsberger, S ;
Loebe, M .
ANNALS OF THORACIC SURGERY, 1999, 68 (02) :742-749