Validation of a dual energy X-ray absorptiometer: Measurement of bone mass and soft tissue composition

被引:51
作者
Madsen, OR
Jensen, JEB
Sorensen, OH
机构
[1] Osteoporosis Research Centre, Copenhagen Municipal Hospital, University of Copenhagen, DK-1399 Copenhagen K
关键词
bone mineral density; dual energy X-ray absorptiometry; fat mass; lean mass; reproducibility;
D O I
10.1007/s004210050204
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We investigated the reproducibility of total and regional body composition measurements performed on a dual energy X-ray absorptiometer (DXA). A group of 38 women aged 21-81 (mean 52.4) years was scanned twice with repositioning to determine intraobserver reproducibility of measurements of bone mineral density (BMD, g.cm(-2)), bone mineral content (EMC, g), lean mass (LM,kg) and fat mass (FM, kg) of the total body and of the major subregions of the body. In addition, the ability of the DXA machine to detect changes in LM and FM (simulated by placing 11.1 and 22.3 kg porcine lard on the body of 11 subjects) was examined, Coefficients of variations calculated from the root mean square averages of individual standard deviations were as follows (BMD, BMC, FM, LM): 1.4%, 1.1%, 1.4%, 1.7% (total body), 2.2%, 2.1%,-,- (head), 2.8%. 2.8%, 2.0%, 3.2% (trunk), 3.6%, 3.9%, 4.0%; 4.9% (alms), 2.7%, 1.3%, 2.6%, 2.8% (legs). Percentage fat (%fat) of exogenous lard was 81.3(SD 3.5)% as assessed by the absorptiometer which corresponded well with the result of chemical analysis (82.5%). Estimated %fat of exogenous lard was not influenced by initial body mass or percentage body fat. Percentages of expected mean values with 11.1 kg lard placed on the body were 99.9 (SD 0.3) for body mass, 100.5 (SD 2.1) for LM, and 99.5 (SD 3.5) for FM. BMD was overestimated by 3.2% (P<0.005) with 11.1 kg lard on the body. BMD as well as BMC increased significantly with 22.3 kg lard on the body (P < 0.005). The results showed that BMD, BMC, LM, and FM of the total body were precisely estimated by the DXA machine used. Regional measurements were less precise. Changes in total body soft tissue composition were precisely and accurately estimated. The lard placed on the body falsely affected BMD and BMC measurements. Changes in body mass could have a similar effect.
引用
收藏
页码:554 / 558
页数:5
相关论文
共 17 条
[1]  
CLARK RR, 1993, MED SCI SPORT EXER, V25, P528
[2]   FACTORS INFLUENCING SHORT-TERM PRECISION OF DUAL X-RAY BONE ABSORPTIOMETRY (DXA) OF SPINE AND FEMUR [J].
ENGELKE, K ;
GLUER, CC ;
GENANT, HK .
CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (01) :19-25
[3]   ASSESSMENT OF THE COMPOSITION OF MAJOR BODY REGIONS BY DUAL-ENERGY X-RAY ABSORPTIOMETRY (DEXA), WITH SPECIAL REFERENCE TO LIMB MUSCLE MASS [J].
FULLER, NJ ;
LASKEY, MA ;
ELIA, M .
CLINICAL PHYSIOLOGY, 1992, 12 (03) :253-266
[4]   ACCURATE ASSESSMENT OF PRECISION ERRORS - HOW TO MEASURE THE REPRODUCIBILITY OF BONE DENSITOMETRY TECHNIQUES [J].
GLUER, CC ;
BLAKE, G ;
LU, Y ;
BLUNT, BA ;
JERGAS, M ;
GENANT, HK .
OSTEOPOROSIS INTERNATIONAL, 1995, 5 (04) :262-270
[5]   MEASUREMENT OF LEAN BODY-MASS AND TOTAL-BODY FAT USING DUAL PHOTON-ABSORPTIOMETRY [J].
GOTFREDSEN, A ;
JENSEN, J ;
BORG, J ;
CHRISTIANSEN, C .
METABOLISM-CLINICAL AND EXPERIMENTAL, 1986, 35 (01) :88-93
[6]   VALIDATION OF BODY-COMPOSITION BY DUAL ENERGY X-RAY ABSORPTIOMETRY (DEXA) [J].
HAARBO, J ;
GOTFREDSEN, A ;
HASSAGER, C ;
CHRISTIANSEN, C .
CLINICAL PHYSIOLOGY, 1991, 11 (04) :331-341
[7]   INFLUENCE OF FAT ON BONE MEASUREMENTS WITH DUAL-ENERGY ABSORPTIOMETRY [J].
HANGARTNER, TN ;
JOHNSTON, CC .
BONE AND MINERAL, 1990, 9 (01) :71-81
[8]   MEASUREMENT OF BONE-MINERAL DENSITY [J].
HASSAGER, C ;
CHRISTIANSEN, C .
CALCIFIED TISSUE INTERNATIONAL, 1995, 57 (01) :1-5
[9]   DUAL-PHOTON ABSORPTIOMETRY - COMPARISON OF BONE-MINERAL AND SOFT-TISSUE MASS MEASUREMENTS INVIVO WITH ESTABLISHED METHODS [J].
HEYMSFIELD, SB ;
WANG, J ;
HESHKA, S ;
KEHAYIAS, JJ ;
PIERSON, RN .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1989, 49 (06) :1283-1289
[10]  
JENSEN LB, 1994, J BONE MINER RES, V9, P459