Application of Doehlert matrix and factorial designs in optimization of experimental variables associated with preconcentration and determination of molybdenum in sea-water by inductively coupled plasma optical emission spectrometry

被引:67
作者
Ferreira, SLC
dos Santos, HC
Fernandes, MS
de Carvalho, MS
机构
[1] Univ Fed Bahia, Inst Quim, Grp Pesquisa Quim Analit, BR-40170290 Salvador, BA, Brazil
[2] CNEN, Inst Engn Nucl, Rio De Janeiro, Brazil
关键词
D O I
10.1039/b109087a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and efficient procedure for the preconcentration and determination of molybdenum in sea-water was developed using solid-phase extraction (SPE) of molybdenum( V) ion as the thiocyanate complex by polyurethane foam and inductively coupled plasma optical emission spectrometry (ICP-OES). The optimization process was carried out using two-level full factorial and Doehlert matrix designs. Four variables (solution volume, shaking time, thiocyanate concentration and hydrochloric acid concentration) were regarded as factors in the optimization. Results of the two-level full factorial design, 2(4) with 16 runs based on the variance analysis (ANOVA), demonstrated that all four factors, as well as the interactions between thiocyanate concentration and time and hydrochloric acid concentration and time, are statistically significant. Doehlert designs were applied in order to determine the optimum conditions for molybdenum preconcentration. The proposed procedure allowed molybdenum determination with a detection limit of 1.5 mug L-1 and a precision, calculated as relative standard deviation (RSD), of 1.8% for a set of 10 measurements for a molybdenum concentration of 10.0 mug L-1 in synthetic sea-water solution. The recovery of molybdenum in the presence of several cations achieved demonstrated that this procedure improved the required selectivity for sea-water analysis. The studied procedure was applied to molybdenum determination in surface sea-water samples collected in Salvador City, Brazil. Results showed good agreement with other reported data from the literature, including data obtained for samples from this same city by another procedure.
引用
收藏
页码:115 / 120
页数:6
相关论文
共 39 条
[1]   Experimental design .2. Optimization [J].
Araujo, PW ;
Brereton, RG .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (02) :63-70
[2]   Optimization of conditions for the preparation of activated carbons from olive-waste cakes [J].
Baçaoui, A ;
Yaacoubi, A ;
Dahbi, A ;
Bennouna, C ;
Luu, RPT ;
Maldonado-Hodar, FJ ;
Rivera-Utrilla, J ;
Moreno-Castilla, C .
CARBON, 2001, 39 (03) :425-432
[3]  
BARROS NETO B, 1995, PLANEJAMENTO OTIMIZA
[4]   EXPERIMENTAL AND THEORETICAL-STUDIES OF THE FACTORS THAT INFLUENCE THE DETERMINATION OF MOLYBDENUM BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROSCOPY [J].
BENZO, Z ;
ARAUJO, P ;
SIERRAALTA, A ;
RUETTE, F .
ANALYTICAL CHEMISTRY, 1993, 65 (08) :1107-1113
[5]   Experimental designs applied to solid-phase derivative spectrophotometry [J].
Bosque-Sendra, JM ;
Nechar, M ;
Molina, MF .
MIKROCHIMICA ACTA, 2000, 134 (1-2) :43-50
[6]   OPTIMIZATION OF ANALYTICAL METHODS BY USING DOEHLERTS DESIGNS [J].
BOSQUESENDRA, JM ;
NECHAR, M ;
RODRIGUEZ, LC ;
MOLINA, MFM .
ANALYTICAL PROCEEDINGS, 1995, 32 (09) :375-377
[7]  
Braun T., 1985, POLYURETHANE FOAM SO
[8]   Multivariate optimization of solvent extraction of Cd(II), Co(II), Cr(VI), Cu(II), Ni(II), Pb(II) and Zn(II) as dibenzyldithiocarbamates and detection by AAS [J].
Camino, M ;
Bagur, MG ;
Sánchez-Viñas, M ;
Gázquez, D ;
Romero, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (06) :638-642
[9]   Selective determination of cobalt using polyurethane foam and 2-(2-benzothiazolylazo)-2-p-cresol as a spectrophotometric reagent [J].
Carvalho, MS ;
Fraga, ICS ;
Neto, KCM ;
Silva, EQ .
TALANTA, 1996, 43 (10) :1675-1680
[10]   Optimisation of the extraction of arsenic species from mussels with low power focused microwaves by applying a Doehlert design [J].
Dagnac, T ;
Padró, A ;
Rubio, R ;
Rauret, G .
ANALYTICA CHIMICA ACTA, 1998, 364 (1-3) :19-30