Electrical impedance tomography: On the path to the Holy Grail

被引:11
作者
Arnold, JH [1 ]
机构
[1] Harvard Univ, Childrens Hosp, Sch Med, Cambridge, MA 02138 USA
关键词
acute lung injury; acute respiratory distress syndrome; barotrauma; lung injury; electrical impedance; mechanical ventilation; physiologic monitoring; respiratory failure; tomography; ventilation; gas exchange;
D O I
10.1097/01.CCM.0000115261.88801.24
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
引用
收藏
页码:894 / 895
页数:2
相关论文
共 15 条
[1]   Monitoring changes in lung air and liquid volumes with electrical impedance tomography [J].
Adler, A ;
Amyot, R ;
Guardo, R ;
Bates, JHT ;
Berthiaume, Y .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (05) :1762-1767
[2]   Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. [J].
Brower, RG ;
Matthay, MA ;
Morris, A ;
Schoenfeld, D ;
Thompson, BT ;
Wheeler, A ;
Wiedemann, HP ;
Arroliga, AC ;
Fisher, CJ ;
Komara, JJ ;
Perez-Trepichio, P ;
Parsons, PE ;
Wolkin, R ;
Welsh, C ;
Fulkerson, WJ ;
MacIntyre, N ;
Mallatratt, L ;
Sebastian, M ;
McConnell, R ;
Wilcox, C ;
Govert, J ;
Thompson, D ;
Clemmer, T ;
Davis, R ;
Orme, J ;
Weaver, L ;
Grissom, C ;
Eskelson, M ;
Young, M ;
Gooder, V ;
McBride, K ;
Lawton, C ;
d'Hulst, J ;
Peerless, JR ;
Smith, C ;
Brownlee, J ;
Pluss, W ;
Kallet, R ;
Luce, JM ;
Gottlieb, J ;
Elmer, M ;
Girod, A ;
Park, P ;
Daniel, B ;
Gropper, M ;
Abraham, E ;
Piedalue, F ;
Glodowski, J ;
Lockrem, J ;
McIntyre, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (18) :1301-1308
[3]  
Brown B. H., 2003, Journal of Medical Engineering & Technology, V27, P97, DOI 10.1080/0309190021000059687
[4]   High-frequency oscillatory ventilation for acute respiratory distress syndrome in adults [J].
Derdak, S ;
Mehta, S ;
Stewart, TE ;
Smith, T ;
Rogers, M ;
Buchman, TG ;
Carlin, B ;
Lowson, S ;
Granton, J .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 166 (06) :801-808
[5]   Detection of local lung air content by electrical impedance tomography compared with electron beam CT [J].
Frerichs, I ;
Hinz, J ;
Herrmann, P ;
Weisser, G ;
Hahn, G ;
Dudykevych, T ;
Quintel, M ;
Hellige, G .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 93 (02) :660-666
[6]   What has computed tomography taught us about the acute respiratory distress syndrome? [J].
Gattinoni, L ;
Caironi, P ;
Pelosi, P ;
Goodman, LR .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (09) :1701-1711
[7]   RELATIONSHIPS BETWEEN LUNG COMPUTED TOMOGRAPHIC DENSITY, GAS-EXCHANGE, AND PEEP IN ACUTE RESPIRATORY-FAILURE [J].
GATTINONI, L ;
PESENTI, A ;
BOMBINO, M ;
BAGLIONI, S ;
RIVOLTA, M ;
ROSSI, F ;
ROSSI, G ;
FUMAGALLI, R ;
MARCOLIN, R ;
MASCHERONI, D ;
TORRESIN, A .
ANESTHESIOLOGY, 1988, 69 (06) :824-832
[8]   Has high-frequency ventilation been inappropriately discarded in adult acute respiratory distress syndrome? [J].
Herridge, MS ;
Slutsky, AS ;
Colditz, GA .
CRITICAL CARE MEDICINE, 1998, 26 (12) :2073-2077
[9]   Monitoring of recruitment and derecruitment by electrical impedance tomography in a model of acute lung injury [J].
Kunst, PWA ;
de Anda, GV ;
Böhm, SH ;
Faes, TJC ;
Lachmann, B ;
Postmus, PE ;
de Vries, PMJW .
CRITICAL CARE MEDICINE, 2000, 28 (12) :3891-3895
[10]   Regional pressure volume curves by electrical impedance tomography in a model of acute lung injury [J].
Kunst, PWA ;
Böhm, SH ;
de Anda, GV ;
Amato, MBP ;
Lachmann, B ;
Postmus, PE ;
de Vries, PMJM .
CRITICAL CARE MEDICINE, 2000, 28 (01) :178-183