Design of segmented poly(ether ester) materials and structures for the tissue engineering of bone

被引:107
作者
Deschamps, AA
Claase, MB
Sleijster, WJ
de Bruijn, JD
Grijpma, DW
Feijen, J
机构
[1] Univ Twente, Inst Biomed Technol, Fac Chem Technol, Dept Polymer Chem & Biomat, NL-7500 AE Enschede, Netherlands
[2] IsoTis, NL-3720 MB Bilthoven, Netherlands
关键词
segmented poly(ether ester)s; degradation; tissue engineering; bone;
D O I
10.1016/S0168-3659(01)00497-7
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, PEOT/PBT segmented copolymers of different compositions have been evaluated as possible scaffold materials for the tissue engineering of bone. By changing the composition of PEOT/PBT copolymers, very different mechanical and swelling behaviors are observed. Tensile strengths vary from 8 to 23 MPa and elongations at break from 500 to 1300%. Water-uptake ranges from 4 up to as high as 210%. The in vitro degradation of PEOT/PBT copolymers occurs both by hydrolysis and oxidation. In both cases degradation is more rapid for copolymers with high PEO content. PEOT/PBT scaffolds with varying porosities and pore sizes have been prepared by molding and freeze-drying techniques in combination with particulate-leaching. The most hydrophilic PEOT/PBT copolymers did not sustain goat bone marrow cell adhesion and growth. However, surface modification by gas plasma treatment showed a very much improved polymer-cell interaction for all PEOT/PBT copolymer compositions. Their mechanical properties, degradability and ability to sustain bone marrow cell growth make PEOT/PBT copolymers excellent materials for bone tissue engineering. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:175 / 186
页数:12
相关论文
共 58 条
[41]  
Roessler M, 2000, J BIOMED MATER RES, V53, P167, DOI 10.1002/(SICI)1097-4636(2000)53:2<167::AID-JBM6>3.3.CO
[42]  
2-A
[43]  
Saad B, 1996, J BIOMED MATER RES, V32, P355
[44]  
Schubert MA, 1997, J BIOMED MATER RES, V34, P519, DOI 10.1002/(SICI)1097-4636(19970315)34:4<519::AID-JBM12>3.0.CO
[45]  
2-7
[46]   SINGLE-POINT DETERMINATION OF INTRINSIC VISCOSITY [J].
SHROFF, RN .
JOURNAL OF APPLIED POLYMER SCIENCE, 1965, 9 (04) :1547-&
[47]  
Solomon O. F., 1962, J APPL POLYM SCI, V6, P683, DOI [10.1002/app.1962.070062414, DOI 10.1002/APP.1962.070062414]
[48]   DEGRADATION OF BIOMATERIALS BY PHAGOCYTE-DERIVED OXIDANTS [J].
SUTHERLAND, K ;
MAHONEY, JR ;
COURY, AJ ;
EATON, JW .
JOURNAL OF CLINICAL INVESTIGATION, 1993, 92 (05) :2360-2367
[49]   Guided tissue fabrication from periosteum using preformed biodegradable polymer scaffolds [J].
Thomson, RC ;
Mikos, AG ;
Beahm, E ;
Lemon, JC ;
Satterfield, WC ;
Aufdemorte, TB ;
Miller, MJ .
BIOMATERIALS, 1999, 20 (21) :2007-2018
[50]   SYNTHESIS AND CHARACTERIZATION OF DEGRADABLE POLY(ANHYDRIDE-CO-IMIDES) [J].
UHRICH, KE ;
GUPTA, A ;
THOMAS, TT ;
LAURENCIN, CT ;
LANGER, R .
MACROMOLECULES, 1995, 28 (07) :2184-2193