Post-source decay time-of-flight study of fragmentation mechanisms of protonated synthetic polymers under matrix-assisted laser desorption/ionization conditions

被引:20
作者
Fournier, I [1 ]
Marie, A [1 ]
Lesage, D [1 ]
Bolbach, G [1 ]
Fournier, F [1 ]
Tabet, JC [1 ]
机构
[1] Univ Paris 06, Lab Chim Struct Organ & Biol, CNRS UMR 7613, F-75252 Paris 05, France
关键词
D O I
10.1002/rcm.629
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Post-source decay (PSD) of three different nylon oligomers desorbed under matrix-assisted laser desorption/ionization (MALDI) conditions was studied and their fragmentation pathways were investigated. The fragmentation of the protonated oligomers is very similar to that of peptides. The b(n)(+), y(n)(+) and z(n)(+) series of ions were observed in abundance in the PSD spectrum. The end groups and the length of the spacer in the repeating unit influence the fragmentation of the different polyamides and the relative abundances of the product ions. Competitive dehydration and deamination reactions were observed, and depend on the nature of the end groups and the repeating units. The PSD spectra are very similar to collision-induced dissociation (CID) spectra obtained under low-energy conditions, implying that the selected precursor ions possess similar average internal energies. All the peaks observed in the PSD spectrum can be rationalized by reasonable fragmentation mechanisms. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:696 / 704
页数:9
相关论文
共 24 条
[1]  
BHAR U, 1992, ANAL CHEM, V68, P2866
[2]   Mass spectrometry of polymers and polymer surfaces [J].
Hanton, SD .
CHEMICAL REVIEWS, 2001, 101 (02) :527-569
[3]  
Jackson AT, 1996, RAPID COMMUN MASS SP, V10, P1668, DOI 10.1002/(SICI)1097-0231(199610)10:13<1668::AID-RCM703>3.0.CO
[4]  
2-I
[5]   LASER DESORPTION IONIZATION OF PROTEINS WITH MOLECULAR MASSES EXCEEDING 10000 DALTONS [J].
KARAS, M ;
HILLENKAMP, F .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2299-2301
[6]  
KAUFMANN R, 1997, INT J MASS SPECTROM, V165, P405
[7]   Desorption behavior and distributions of fluorinated polymers in MALDI and electrospray ionization mass spectrometry [J].
Latourte, L ;
Blais, JC ;
Tabet, JC ;
Cole, RB .
ANALYTICAL CHEMISTRY, 1997, 69 (14) :2742-2750
[8]   Application of nonpolar matrices for the analysis of low molecular weight nonpolar synthetic polymers by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry [J].
Macha, SF ;
Limbach, PA ;
Savickas, PJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (08) :731-737
[9]   Characterization of synthetic polymers by MALDI-TOF/MS: Investigation into new methods of sample target preparation and consequence on mass spectrum finger print [J].
Marie, A ;
Fournier, F ;
Tabet, JC .
ANALYTICAL CHEMISTRY, 2000, 72 (20) :5106-5114
[10]   Characterization of polyether and polyester polyurethane soft blocks using MALDI mass spectrometry [J].
Mehl, JT ;
Murgasova, R ;
Dong, X ;
Hercules, DM ;
Nefzger, H .
ANALYTICAL CHEMISTRY, 2000, 72 (11) :2490-2498