Vision tests in the mouse: Functional phenotyping with electroretinography

被引:74
作者
Tanimoto, Naoyuki [1 ]
Muehlfriedel, Regine L. [1 ]
Fischer, M. Dominik [1 ]
Fahl, Edda [1 ]
Humphries, Peter [2 ]
Biel, Martin [3 ,4 ]
Seeliger, Mathias W. [1 ]
机构
[1] Univ Tubingen, Inst Ophthalm Res, Ctr Ophthalmol, Ocular Neurodegenerat Res Grp, Schleichstr 4-3, D-72076 Tubingen, Germany
[2] Trinity Coll Dublin, Dept Genet, Ocular Genet Unit, Dublin 2, Ireland
[3] Univ Munich, Ctr Integrated Prot Sci CIPS M, D-81377 Munich, Germany
[4] Univ Munich, Zentrum Pharmaforsch, Dept Pharm, D-81377 Munich, Germany
来源
FRONTIERS IN BIOSCIENCE-LANDMARK | 2009年 / 14卷
关键词
Animal model; Cone; Electroretinogram; Flash; Flicker; Rod; Review; DEFICIENT MICE; CONE FUNCTION; IN-VIVO; RPE65; MODEL; ADAPTATION; RECOVERY; THERAPY; LIGHT;
D O I
10.2741/3409
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Electroretinography (ERG) is an established diagnostic technique in clinical ophthalmology and provides objective information about retinal function. This technique is also applied in basic research, where animal models of hereditary retinopathies have significantly contributed to our understanding of the composition of ERG responses in general and how retinal degenerative pathologies alter retinal function specifically. Indeed, electrophysiologic assessment of transgenic mice, which are genetically engineered to mimic human mutations that lead to retinal diseases, can be well compared with clinical data. Furthermore, limitations on examinations (e.g. length of measurement, range of light intensity) are much less of a concern when assessing mice compared to human patients. In order to measure and analyze retinal responses properly, several important aspects have to be considered. This paper focuses on these aspects, and shows exemplary ERG data which were obtained from normal wild-type mice and from transgenic mice with specific functional properties, namely Rho(-/-) (rod opsin knockout, cone function only), and Cnga3(-/-)(cone CNG channel deficient, rod function only) to illustrate rod and cone system contributions to ERG responses.
引用
收藏
页码:2730 / 2737
页数:8
相关论文
共 20 条
[1]   Mpp4 recruits Psd95 and Veli3 towards the photoreceptor synapse [J].
Aartsen, WM ;
Kantardzhieva, A ;
Klooster, J ;
van Rossum, AGSH ;
van de Pavert, SA ;
Versteeg, I ;
Cardozo, BN ;
Tonagel, F ;
Beck, SC ;
Tanimoto, N ;
Seeliger, MW ;
Wijnholds, J .
HUMAN MOLECULAR GENETICS, 2006, 15 (08) :1291-1302
[2]   Selective loss of cone function in mice lacking the cyclic nucleotide-gated channel CNG3 [J].
Biel, M ;
Seeliger, M ;
Pfeifer, A ;
Kohler, K ;
Gerstner, A ;
Ludwig, A ;
Jaissle, G ;
Fauser, S ;
Zrenner, E ;
Hofmann, F .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1999, 96 (13) :7553-7557
[3]   Rb-mediated neuronal differentiation through cell-cycle-independent regulation of E2f3a [J].
Chen, Danian ;
Opavsky, Rene ;
Pacal, Marek ;
Tanimoto, Naoyuki ;
Wenzel, Pamela ;
Seeliger, Mathias W. ;
Leone, Gustavo ;
Bremner, Rod .
PLOS BIOLOGY, 2007, 5 (07) :1504-1519
[5]  
Jaissle GB, 2001, INVEST OPHTH VIS SCI, V42, P506
[6]   Effect of late-stage therapy on disease progression in AAV-mediated rescue of photoreceptor cells in the retinoschisin-deficient mouse [J].
Janssen, Andreas ;
Min, Seok H. ;
Molday, Laurie L. ;
Tanimoto, Naoyuki ;
Seeliger, Mathias W. ;
Hauswirth, William W. ;
Molday, Robert S. ;
Weber, Bernhard H. F. .
MOLECULAR THERAPY, 2008, 16 (06) :1010-1017
[7]   Delayed dark adaptation in 11-cis-retinol dehydrogenase-deficient mice -: A role of RDH11 in visual processes in vivo [J].
Kim, TS ;
Maeda, A ;
Maeda, T ;
Heinlein, C ;
Kedishvili, N ;
Palczewski, K ;
Nelson, PS .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2005, 280 (10) :8694-8704
[8]   The effect of body temperature on the murine electroretinogram [J].
Kong, H ;
Gouras, P .
DOCUMENTA OPHTHALMOLOGICA, 2003, 106 (03) :239-242
[9]   Recovery phase of the murine rod photoresponse reconstructed from electroretinographic recordings [J].
Lyubarsky, AL ;
Pugh, EN .
JOURNAL OF NEUROSCIENCE, 1996, 16 (02) :563-571
[10]   Standard for clinical electroretinography (2004 update) [J].
Marmor, MF ;
Holder, GE ;
Seeliger, MW ;
Yamamoto, S .
DOCUMENTA OPHTHALMOLOGICA, 2004, 108 (02) :107-114