Comparison Between DEXA and Finite Element Studies in the Long-Term Bone Remodeling of an Anatomical Femoral Stem

被引:18
作者
Herrera, A. [1 ,2 ]
Panisello, J. J. [1 ,2 ]
Ibarz, E. [3 ]
Cegonino, J. [3 ]
Puertolas, J. A. [4 ]
Gracia, L. [3 ]
机构
[1] Univ Zaragoza, Dept Surg, E-50009 Zaragoza, Spain
[2] Miguel Servet Univ Hosp, Dept Orthopaed Surg & Traumatol, Zaragoza 50009, Spain
[3] Univ Zaragoza, Dept Mech Engn, Zaragoza 50018, Spain
[4] Univ Zaragoza, Dept Sci & Technol Mat, Zaragoza 50018, Spain
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2009年 / 131卷 / 04期
关键词
biomechanics; biomedical measurement; bone; densitometry; orthopaedics; physiological models; prosthetics; stress analysis; TOTAL HIP-ARTHROPLASTY; X-RAY ABSORPTIOMETRY; 3-YEAR FOLLOW-UP; MINERAL DENSITY; PROXIMAL FEMUR; CLINICAL CONSEQUENCES; POSTMORTEM-ANALYSIS; ELASTIC PROPERTIES; CORTICAL BONE; TAPER-DESIGN;
D O I
10.1115/1.3072888
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
The implantation of a cemented or cementless femoral stem changes the physiological load transfer on the femur producing an effect on the bone called adaptative remodeling. The patterns of this remodeling are attributed to mechanical and biological factors, and those changes in bone mineral density have been determined in long-term densitometry studies. This technique has proved to be a useful tool able to quantify small changes in bone density in different femoral areas, and it is considered to be ideal for long-term studies. On the other hand, the finite element (FE) simulation allows the study of the biomechanical changes produced in the femur after the implantation of a femoral stem. The aim of this study was to contrast the findings obtained from a 5 year follow-up densitometry study that used a newly designed femoral stem (73 patients were included in this study), with the results obtained using a finite element simulation that reproduces the pattern of load transfer that this stem causes on the femur. In this study we have obtained a good comparison between the results of stress of FE simulation and the bone mass values of the densitometry study establishing a ratio between the increases in stress (%) versus the increases in bone density (%). Hence, the changes in bone density in the long term, compared with the healthy femur, are due to different load transfers after stem implantation. It has been checked that in the Gruen zone 7 at 5 years, the most important reduction in stress (7.85%) is produced, which coincides with the highest loss of bone mass (23.89%). Furthermore, the simulation model can be used with different stems with several load conditions and at different time periods to carry out the study of biomechanical behavior in the interaction between the stem and the femur, explaining the evolution of bone density in accordance to Wolff's law, which validates the simulation model.
引用
收藏
页数:11
相关论文
共 67 条
[1]
An age-related medullary expansion can have implications for the long-term fixation of hip prostheses [J].
Ahlborg, HG ;
Johnell, O ;
Karlsson, MK .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (02) :154-159
[2]
ELASTIC-MODULUS OF TRABECULAR BONE MATERIAL [J].
ASHMAN, RB ;
RHO, JY .
JOURNAL OF BIOMECHANICS, 1988, 21 (03) :177-181
[3]
A CONTINUOUS WAVE TECHNIQUE FOR THE MEASUREMENT OF THE ELASTIC PROPERTIES OF CORTICAL BONE [J].
ASHMAN, RB ;
COWIN, SC ;
VANBUSKIRK, WC ;
RICE, JC .
JOURNAL OF BIOMECHANICS, 1984, 17 (05) :349-361
[4]
HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[5]
Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[6]
The periprosthetic bone remodelling process - signs of vital bone reaction [J].
Braun, A ;
Papp, J ;
Reiter, A .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 :S7-S10
[7]
Changes in bone mineral density in the proximal femur after cementless total hip arthroplasty - A five-year longitudinal study [J].
Brodner, W ;
Bitzan, P ;
Lomoschitz, F ;
Krepler, P ;
Jankovsky, R ;
Lehr, S ;
Kainberger, F ;
Gottsauner-Wolf, F .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (01) :20-26
[8]
Long-term clinical consequences of stress-shielding after total hip arthroplasty without cement [J].
Bugbee, WD ;
Culpepper, WJ ;
Engh, CA ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (07) :1007-1012
[9]
ACCURACY OF DEXA MEASUREMENT OF BONE-MINERAL DENSITY AFTER TOTAL HIP-ARTHROPLASTY [J].
COHEN, B ;
RUSHTON, N .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (03) :479-483
[10]
Ten-year follow-up of an anatomical hydroxyapatite-coated total hip prosthesis [J].
Cortés, VC ;
Sebastiá, JJP ;
Rodríguez, AH ;
Bona, AP ;
Martín, AM ;
Barcos, LH ;
García-Dihinx, L .
INTERNATIONAL ORTHOPAEDICS, 2006, 30 (02) :84-90