Fully Integrated Artificial Pancreas in Type 1 Diabetes: Modular Closed-Loop Glucose Control Maintains Near Normoglycemia

被引:197
作者
Breton, Marc [1 ]
Farret, Anne [2 ,3 ]
Bruttomesso, Daniela [4 ]
Anderson, Stacey [1 ]
Magni, Lalo [5 ]
Patek, Stephen [1 ]
Man, Chiara Dalla [6 ]
Place, Jerome [2 ,3 ]
Demartini, Susan [1 ]
Del Favero, Simone [6 ]
Toffanin, Chiara [5 ]
Hughes-Karvetski, Colleen [1 ]
Dassau, Eyal [7 ,8 ]
Zisser, Howard [7 ,8 ]
Doyle, Francis J., III [7 ]
De Nicolao, Giuseppe [5 ]
Avogaro, Angelo [4 ]
Cobelli, Claudio [6 ]
Renard, Eric [2 ,3 ]
Kovatchev, Boris [1 ]
机构
[1] Univ Virginia, Ctr Diabet Technol, Charlottesville, VA 22903 USA
[2] Univ Montpellier, Univ Hosp Montpellier, Dept Endocrinol Diabet & Nutr, INSERM,Clin Invest Ctr 1001, F-34059 Montpellier, France
[3] Univ Montpellier, Inst Funct Genom, CNRS, INSERM,U661,UMR5203, F-34059 Montpellier, France
[4] Univ Padua, Dept Internal Med, Unit Metab Dis, I-35100 Padua, Italy
[5] Univ Pavia, Dept Comp Engn & Syst Sci, I-27100 Pavia, Italy
[6] Univ Padua, Dept Informat Engn, Padua, Italy
[7] Univ Calif Santa Barbara, Santa Barbara, CA 93106 USA
[8] Sansum Diabet Res Inst, Santa Barbara, CA USA
关键词
INSULIN DELIVERY; INFUSION; ADULTS; SYSTEM; MODEL;
D O I
10.2337/db11-1445
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Integrated closed-loop control (CLC), combining continuous glucose monitoring (CGM) with insulin pump (continuous subcutaneous insulin infusion [CSII]), known as artificial pancreas, can help optimize glycemic control in diabetes. We present a fundamental modular concept for CLC design, illustrated by clinical studies involving 11 adolescents and 27 adults at the Universities of Virginia, Padova, and Montpellier. We tested two modular CLC constructs: standard control to range (sCTR), designed to augment pump plus CGM by preventing extreme glucose excursions; and enhanced control to range (eCTR), designed to truly optimize control within near normoglycemia of 3.9-10 trillion. The CLC system was fully integrated using automated data transfer CGM -> algorithm -> CSII All studies used randomized crossover design comparing CSII versus CLC during identical 22-h hospitalizations including meals, overnight rest, and 30-min exercise. sCTR increased significantly the time in near normoglycemia from 61 to 74%, simultaneously reducing hypoglycemia 2.7-fold. eCTR improved mean blood glucose from 7.73 to 6.68 nunol/L without increasing hypoglycemia, achieved 97% in near normoglycemia and 77% in tight glycemic control, and reduced variability overnight. In conclusion, sCTR and eCTR represent sequential steps toward automated CLC, preventing extremes (sCTR) and further optimizing control (eCTR). This approach inspires compelling new concepts: modular assembly, sequential deployment, testing, and clinical acceptance of custom-built CLC systems tailored to individual patient needs. Diabetes 61:2230-2237, 2012
引用
收藏
页码:2230 / 2237
页数:8
相关论文
共 35 条
[1]   ARTIFICIAL ENDOCRINE PANCREAS [J].
ALBISSER, AM ;
LEIBEL, BS ;
EWART, TG ;
DAVIDOVAC, Z ;
BOTZ, CK ;
ZINGG, W .
DIABETES, 1974, 23 (05) :389-396
[2]  
[Anonymous], IEEE T BIOMED ENG
[3]   MD-Logic Artificial Pancreas System A pilot study in adults with type 1 diabetes [J].
Atlas, Eran ;
Nimri, Revital ;
Miller, Shahar ;
Grunberg, Eli A. ;
Phillip, Moshe .
DIABETES CARE, 2010, 33 (05) :1072-1076
[4]  
Bode B W, 2000, Diabetes Technol Ther, V2 Suppl 1, pS35
[5]   Statistical Tools to Analyze Continuous Glucose Monitor Data [J].
Clarke, William ;
Kovatchev, Boris .
DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 :S45-S54
[6]  
Clemens A H, 1977, Horm Metab Res, VSuppl 7, P23
[7]   Artificial Pancreas Past, Present, Future [J].
Cobelli, Claudio ;
Renard, Eric ;
Kovatchev, Boris .
DIABETES, 2011, 60 (11) :2672-2682
[8]  
Cobelli Claudio, 2009, IEEE Rev Biomed Eng, V2, P54, DOI 10.1109/RBME.2009.2036073
[9]   HYPOGLYCEMIA - THE LIMITING FACTOR IN THE MANAGEMENT OF IDDM [J].
CRYER, PE .
DIABETES, 1994, 43 (11) :1378-1389
[10]  
Dassau E, 2010, DIABETES, V59, pA94