Statistical Tools to Analyze Continuous Glucose Monitor Data

被引:167
作者
Clarke, William [1 ]
Kovatchev, Boris
机构
[1] Univ Virginia, Dept Pediat, Hlth Sci Ctr, Div Pediat Endocrinol, Charlottesville, VA 22908 USA
基金
美国国家卫生研究院;
关键词
CLINICAL ACCURACY; BLOOD-GLUCOSE; SENSORS;
D O I
10.1089/dia.2008.0138
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Continuous glucose monitors (CGMs) generate data streams that are both complex and voluminous. The analyses of these data require an understanding of the physical, biochemical, and mathematical properties involved in this technology. This article describes several methods that are pertinent to the analysis of CGM data, taking into account the specifics of the continuous monitoring data streams. These methods include: (1) evaluating the numerical and clinical accuracy of CGM. We distinguish two types of accuracy metrics-numerical and clinical each having two subtypes measuring point and trend accuracy. The addition of trend accuracy, e. g., the ability of CGM to reflect the rate and direction of blood glucose (BG) change, is unique to CGM as these new devices are capable of capturing BG not only episodically, but also as a process in time. (2) Statistical approaches for interpreting CGM data. The importance of recognizing that the basic unit for most analyses is the glucose trace of an individual, i.e., a time-stamped series of glycemic data for each person, is stressed. We discuss the use of risk assessment, as well as graphical representation of the data of a person via glucose and risk traces and Poincare plots, and at a group level via Control Variability-Grid Analysis. In summary, a review of methods specific to the analysis of CGM data series is presented, together with some new techniques. These methods should facilitate the extraction of information from, and the interpretation of, complex and voluminous CGM time series.
引用
收藏
页码:S45 / S54
页数:10
相关论文
共 23 条
[1]   Do existing measures of Poincare plot geometry reflect nonlinear features of heart rate variability? [J].
Brennan, M ;
Palaniswami, M ;
Kamen, P .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (11) :1342-1347
[2]  
Breton Marc D, 2008, J Diabetes Sci Technol, V2, P495
[3]  
Childs BP, 2005, DIABETES CARE, V28, P1245
[4]   Evaluating Clinical Accuracy of Continuous Glucose Monitoring Systems: Continuous Glucose - Error Grid Analysis (CG-EGA) [J].
Clarke, William L. ;
Anderson, Stacey ;
Kovatchev, Boris .
CURRENT DIABETES REVIEWS, 2008, 4 (03) :193-199
[5]  
Clarke William L, 2007, J Diabetes Sci Technol, V1, P669
[6]   Evaluating the clinical accuracy of two continuous glucose sensors using continuous glucose-error grid analysis [J].
Clarke, WL ;
Anderson, S ;
Farhy, L ;
Breton, M ;
Gonder-Frederick, L ;
Cox, D ;
Kovatchev, B .
DIABETES CARE, 2005, 28 (10) :2412-2417
[7]   EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE [J].
CLARKE, WL ;
COX, D ;
GONDERFREDERICK, LA ;
CARTER, W ;
POHL, SL .
DIABETES CARE, 1987, 10 (05) :622-628
[8]   STABILITY OF REACTED CHEMSTRIP BG [J].
COX, D ;
HERRMAN, J ;
SNYDER, A ;
GONDERFREDERICK, L ;
RESCHKE, J ;
CLARKE, W .
DIABETES CARE, 1988, 11 (03) :288-291
[9]  
*FOOD DRUG ADM, SUMM SAF EFF DAT STS
[10]  
*FOOD DRUG ADM, SUMM SAF EFF DAT FRE