Demonstration of pulmonary embolism with dynamic gadolinium-enhanced spiral CT

被引:20
作者
Coche, EE [1 ]
Hammer, FD [1 ]
Goffette, PP [1 ]
机构
[1] Univ Louvain, St Luc Univ Hosp, Dept Radiol, B-1200 Brussels, Belgium
关键词
pulmonary embolism; CT; MR imaging; contrast medium;
D O I
10.1007/s003300100840
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The authors report a case of successful detection of pulmonary embolism using gadolinium-enhanced spiral CT (Gadodiamide, 0.4 mmol/kg, 2 ml/s, delay 18 s) in a 77-year-old woman, with previous allergy to iodinated contrast medium, and renal failure, who presented with pulmonary arterial hypertension. Doppler ultrasound of the lower limbs was first performed and revealed a deep venous thrombosis of the right lower limb. To establish if venous thrombosis was the cause of pulmonary hypertension and to confirm that pulmonary endarterectomy was not indicated in this situation, several imaging modalities were performed. Lung scintigraphy and MRI were non-diagnostic. Gadolinium-enhanced spiral CT demonstrated a large thrombus located proximally and in a segmental artery of the right lower lobe. This case illustrates the potential usefulness of gadolinium as alternative contrast agent with spiral CT to diagnose pulmonary embolism and elucidate the cause of pulmonary arterial hypertension in a patient with some contraindications for iodinated contrast medium injection.
引用
收藏
页码:2306 / 2309
页数:4
相关论文
共 10 条
[1]
GD-DTPA AS A CONTRAST AGENT IN CT [J].
BLOEM, JL ;
WONDERGEM, J .
RADIOLOGY, 1989, 171 (02) :578-579
[2]
Diagnostic usefulness of lung SPET in pulmonary thromboembolism: An outcome study [J].
Corbus, HF ;
Seitz, JP ;
Larson, RK ;
Stobbe, DE ;
Wooten, W ;
Sayre, JW ;
Chavez, RD ;
Unguez, CE .
NUCLEAR MEDICINE COMMUNICATIONS, 1997, 18 (10) :897-906
[3]
Gadolinium as a CT contrast agent: Assessment in a porcine model [J].
Gierada, DS ;
Bae, KT .
RADIOLOGY, 1999, 210 (03) :829-834
[4]
Acute pulmonary embolism: Diagnosis with MR angiography [J].
Gupta, A ;
Frazer, CK ;
Ferguson, JM ;
Kumar, AB ;
Davis, SJ ;
Fallon, MJ ;
Morris, IT ;
Drury, PJ ;
Cala, LA .
RADIOLOGY, 1999, 210 (02) :353-359
[5]
Gadolinium dimeglumine: an alternative contrast agent for digital subtraction angiography [J].
Hammer, FD ;
Goffette, PP ;
Malaise, J ;
Mathurin, P .
EUROPEAN RADIOLOGY, 1999, 9 (01) :128-136
[6]
RENAL TOLERANCE OF GADOLINIUM-DTPA DIMEGLUMINE IN PATIENTS WITH CHRONIC-RENAL-FAILURE [J].
HAUSTEIN, J ;
NIENDORF, HP ;
KRESTIN, G ;
LOUTON, T ;
SCHUHMANNGIAMPIERI, G ;
CLAUSS, W ;
JUNGE, W .
INVESTIGATIVE RADIOLOGY, 1992, 27 (02) :153-156
[7]
GADOPENTETATE DIMEGLUMINE AS AN ALTERNATIVE CONTRAST MATERIAL FOR USE IN ANGIOGRAPHY [J].
KINNO, Y ;
ODAGIRI, K ;
ANDOH, K ;
ITOH, Y ;
TARAO, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (06) :1293-1294
[8]
PALLA A, 1988, J NUCL MED ALLIED S, V32, P27
[9]
GD-DTPA - AN ALTERNATIVE CONTRAST-MEDIUM FOR CT [J].
QUINN, AD ;
OHARE, NJ ;
WALLIS, FJ ;
WILSON, GF .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (04) :634-636
[10]
WORSLEY DF, 1995, J NUCL MED, V36, P2380