Magnetic resonance-guided coronary artery stent placement in a swine model

被引:118
作者
Spuentrup, E
Ruebben, A
Schaeffter, T
Manning, WJ
Günther, RW
Buecker, A
机构
[1] Rhein Westfal TH Aachen, Univ Hosp, Dept Diagnost Radiol, D-52057 Aachen, Germany
[2] Philips Res Labs, Hamburg, Germany
[3] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Boston, MA 02215 USA
[4] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[5] Harvard Univ, Sch Med, Boston, MA USA
关键词
magnetic resonance imaging; coronary disease; stents;
D O I
10.1161/hc0702.104165
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Magnetic resonance (MR)-guided coronary artery stent placement is a challenging vascular intervention because of the small size of the coronary arteries combined with incessant motion during the respiratory and cardiac cycles. These obstacles necessitate higher temporal and higher spatial resolution real-time MR imaging techniques when compared with interventional peripheral MR angiography. Methods and Results-A new, ultrafast, real-tithe MR imaging technique that combines steady-state free precession (SSFP) for high signal-to-noise ratio and radial k-space sampling (rSSFP) for motion artifact suppression was implemented on a 1.5-T clinical whole-body interventional MR scanner. The sliding window reconstruction technique yielded a frame rate of 15/s allowing for data acquisition during free breathing and without cardiac triggering. Eleven balloon-expandable stainless steel coronary stents were placed in both coronary arteries of 7 pigs (40 to 70 kg body weight) using a nitinol guidewire and passive device visualization. Position of the coronary stents was controlled by a navigator-gated free-breathing ECG-triggered three-dimensional SSFP coronary MRA sequence and confirmed visually on the ex vivo heart. The presented real-time MR imaging sequence reliably allowed for high-quality coronary MR fluoroscopy without motion artifacts in all pigs. Ten of 11 coronary stents were correctly placed under MR guidance. One stent dislodged proximally from the left main coronary artery because of too-small balloon size. Stent dislocation was correctly predicted during real-time MR imaging. Conclusion-The presented approach allows for real-time MR-guided coronary artery stent placement in a swine model.
引用
收藏
页码:874 / 879
页数:6
相关论文
共 45 条
[1]   High resolution intravascular MRI and MRS by using a catheter receiver coil [J].
Atalar, E ;
Bottomley, PA ;
Ocali, O ;
Correia, LCL ;
Kelemen, MD ;
Lima, JAC ;
Zerhouni, EA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) :596-605
[2]   MR-guided endovascular interventions: Susceptibility-based catheter and near-real-time imaging technique [J].
Bakker, CJ ;
Hoogeveen, RM ;
Hurtak, WF ;
vanVaals, JJ ;
Viergever, MA ;
Mali, WPTM .
RADIOLOGY, 1997, 202 (01) :273-276
[3]  
Barger AV, 2000, MAGN RESON MED, V43, P503, DOI 10.1002/(SICI)1522-2594(200004)43:4<503::AID-MRM3>3.0.CO
[4]  
2-0
[5]  
Botnar RM, 2000, CIRCULATION, V102, P2582
[6]   Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA [J].
Botnar, RM ;
Stuber, M ;
Danias, PG ;
Kissinger, KV ;
Manning, WJ .
CIRCULATION, 1999, 99 (24) :3139-3148
[7]  
Buecker A, 2000, J MAGN RESON IMAGING, V12, P616, DOI 10.1002/1522-2586(200010)12:4<616::AID-JMRI15>3.0.CO
[8]  
2-F
[9]  
Cutlip DE, 2001, CIRCULATION, V103, P1967
[10]   Coronary stent implantation: a panacea for the interventional cardiologist? [J].
De Feyter, PJ ;
Foley, D .
EUROPEAN HEART JOURNAL, 2000, 21 (21) :1719-1726