Detection and quantification of Legionella pneumophila in water samples using competitive PCR

被引:10
作者
Declerck, Priscilla
Behets, Jonas
Lammertyn, Elke
Lebeau, Ilya
Anne, Jozef
Ollevier, Frans
机构
[1] Katholieke Univ Leuven, Inst Zool, Aquat Ecol Lab, B-3000 Louvain, Belgium
[2] Katholieke Univ Leuven, Rega Inst, Bacteriol Lab, B-3000 Louvain, Belgium
关键词
Legionella pneumophila; competitive PCR; cost-effective; cooling tower water; tap water; sensitive detection;
D O I
10.1139/W05-156
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The presence of high levels of Legionella pneumophila in man-made aquatic systems correlates with the incidence of nosocomial Legionnaires' disease. This requires a rapid, reliable, and sensitive quantification of L. pneumophila concentrations in suspected water systems. In this research, a homologous competitor was developed and evaluated in a L. pneumophila competitive polymerase chain reaction (cPCR) to quantify this human pathogen in a quick, cost-effective, and reliable way. Accuracy of cPCR was evaluated by analyzing cooling tower and tap water samples spiked with known concentrations of L. pneumophila bacteria, in parallel with the standard culture method. Legionella pneumophila amounts detected and calculated from cPCR and culture correlated very well: r = 0.998, P = 0.002 for tap water and r = 0.990, P = 0.009 for cooling tower water. Nevertheless, for both kinds of water samples, mean numbers of L. pneumophila calculated from cPCR results were always higher than those obtained by culture. This study makes it clear that the rapid, sensitive, and cost-effective L. pneumophila cPCR is a promising alternative to the standard time-consuming culture method and expensive real-time PCR to enumerate L. pneumophila bacteria in environmental water samples.
引用
收藏
页码:584 / 590
页数:7
相关论文
共 27 条
[1]   Rapid detection and enumeration of Legionella pneumophila in hot water systems by solid-phase cytometry [J].
Aurell, H ;
Catala, P ;
Farge, P ;
Wallet, F ;
Le Brun, M ;
Helbig, JH ;
Jarraud, S ;
Lebaron, P .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2004, 70 (03) :1651-1657
[2]   Detection of Legionella pneumophila using a real-time PCR hybridization assay [J].
Ballard, AL ;
Fry, NK ;
Chan, L ;
Surman, SB ;
Lee, JV ;
Harrison, TG ;
Towner, KJ .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (11) :4215-4218
[3]  
BEST M, 1983, LANCET, V2, P307
[4]   Enumerating ammonia-oxidizing bacteria in environmental samples using competitive PCR [J].
Bjerrum, L ;
Kjær, T ;
Ramsing, NB .
JOURNAL OF MICROBIOLOGICAL METHODS, 2002, 51 (02) :227-239
[5]   Impact of non-Legionella bacteria on the uptake and intracellular replication of Legionella pneumophila in Acanthamoeba castellanii and Naegleria lovaniensis [J].
Declerck, P ;
Behets, J ;
Delaedt, Y ;
Margineanu, A ;
Lammertyn, E ;
Ollevier, F .
MICROBIAL ECOLOGY, 2005, 50 (04) :536-549
[6]   PCR as a test for the presence or absence of Legionella in (cooling) water [J].
Declerck, P ;
Vereist, L ;
Duvivier, L ;
Van Damme, A ;
Olleviler, F .
WATER SCIENCE AND TECHNOLOGY, 2003, 47 (03) :103-107
[7]   Enumeration of Porphyromonas gingivalis, Prevotella intermedia and Actinobacillus actinomycetemcomitans in subgingival plaque samples by a quantitative-competitive PCR method [J].
Doungudomdacha, S ;
Rawlinson, A ;
Douglas, CWI .
JOURNAL OF MEDICAL MICROBIOLOGY, 2000, 49 (10) :861-874
[8]   Direct detection of Legionella species from bronchoalveolar lavage and open lung biopsy specimens:: Comparison of LightCycler PCR, in situ hybridization, direct fluorescence antigen detection, and culture [J].
Hayden, RT ;
Uhl, JR ;
Qian, X ;
Hopkins, MK ;
Aubry, MC ;
Limper, AH ;
LLoyd, RV ;
Cockerill, FR .
JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (07) :2618-2626
[9]   Comparative evaluation of PCR assays for the robust molecular detection of Mycobacterium avium subsp paratuberculosis [J].
Ikonomopoulos, J ;
Gazouli, M ;
Pavlik, I ;
Bartos, M ;
Zacharatos, P ;
Xylouri, E ;
Papalambros, E ;
Gorgoulis, V .
JOURNAL OF MICROBIOLOGICAL METHODS, 2004, 56 (03) :315-321
[10]  
*INT ORG STAND, 1998, WAT QUAL 4