An automated HPLC method for the fractionation of polychlorinated biphenyls, polychlorinated dibenzo-p-dioxins, and polychlorinated dibenzofurans in fish tissue on a porous graphitic carbon column

被引:19
作者
Echols, K [1 ]
Gale, R [1 ]
Tillitt, D [1 ]
Schwartz, T [1 ]
OLaughlin, J [1 ]
机构
[1] UNIV MISSOURI, DEPT CHEM, COLUMBIA, MO 65201 USA
关键词
PCBs; PCDDs; PCDFs; porous graphitic carbon;
D O I
10.1002/etc.5620160805
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The Ah (aryl-hydrocarbon) hydroxylase-receptor active polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were fractionated by an automated high-performance liquid chromatography (HPLC) system using the Hypercarb(TM) porous graphitic carbon (PGC) column. This commercially available column was used to fractionate the di-, mono-, and non-ortho PCBs into three fractions for gas chromatography (GC)/electron capture detection analysis, and a fourth fraction containing the PCDDs/PCDFs for GC/mass spectrometry analysis. The recoveries of the PCBs ranged from 68 to 96%, and recoveries of the PCDDs/PCDFs ranged from 74 to 123%. The PGC column has the advantage of faster separations (110 min versus 446 min) and less solvent use (275 mi versus 1,100 ml) compared with automated fractionation of these compounds on activated carbon (PX-21), while still affording good separation of the classes. The PGC-column may have an advantage over the pyrenyl-based HPLC method because it has a greater loading capacity (400 mu g total PCBs versus 250 mu g). Overall, the PGC is a standard column that provides reproducible fractionation of PCDD/PCDFs and PCBs for analytical measurement in environmental samples.
引用
收藏
页码:1590 / 1597
页数:8
相关论文
共 37 条
[31]   DETERMINATION OF COPLANAR POLYCHLORINATED BIPHENYL (CB) CONGENERS IN SEAL TISSUES BY CHROMATOGRAPHY ON ACTIVE-CARBON, DUAL-COLUMN HIGH-RESOLUTION GC ECD AND HIGH-RESOLUTION GC HIGH-RESOLUTION MS [J].
STORRHANSEN, E ;
CEDERBERG, T .
CHEMOSPHERE, 1992, 24 (09) :1181-1196
[32]   HPLC CLEANUP PROCEDURES FOR THE DETERMINATION OF 2,3,7,8-TCDD IN FISH TISSUE [J].
THOMPSON, TS ;
SCHELLENBERG, DH ;
NAIKWADI, KP ;
KARASEK, FW .
CHEMOSPHERE, 1989, 19 (1-6) :45-50
[33]   DUAL-COLUMN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC CLEANUP PROCEDURE FOR THE DETERMINATION OF POLYCHLORINATED DIBENZO-PARA-DIOXINS AND DIBENZOFURANS IN FISH TISSUE [J].
THOMPSON, TS ;
KOLIC, TM ;
MACPHERSON, KA .
JOURNAL OF CHROMATOGRAPHY, 1991, 543 (01) :49-58
[34]  
Tiernan TO, 1983, CHLORINATED DIOXINS, P211
[35]  
TUINSTRA LGMT, 1990, HRC-J HIGH RES CHROM, V13, P797, DOI 10.1002/jhrc.1240131202
[36]  
*US EPA, 1990, EPA600390022
[37]  
WILLIAMS LL, 1995, TOXICOL ENVIRON CHEM, V51, P229