Implantation of an inactive epiretinal poly(dimethyl siloxane) electrode array in dogs

被引:30
作者
Güven, D
Weiland, JD
Maghribi, M
Davidson, JC
Mahadevappa, M
Roizenblatt, R
Qiu, QT
Krulevitz, P
Wang, XP
LaBree, L
Humayun, MS
机构
[1] Univ So Calif, Doheny Eye Inst, Doheny Retina Inst, Keck Sch Med,Dept Ophthalmol, Los Angeles, CA USA
[2] Lawrence Livermore Natl Lab, Livermore, CA USA
[3] Univ So Calif, Keck Sch Med, Dept Prevent Med, Los Angeles, CA USA
关键词
retinal prosthesis; poly(dimethylsiloxane); array; optical coherence tomography; implantation; biocompatibility; retinal nerve fibre layer;
D O I
10.1016/j.exer.2005.05.008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The aim of this study is to investigate the long-term, mechanical biocompatibility of a polymer microtechnology that can be used to position electrodes in close proximity to the retina. Poly(dimethylsiloxane) (PDMS) arrays were manufactured by soft-lithography at Lawrence Livermore National Laboratory. The PDMS implant measured 4 mm X 40 mm X 55-60 mu m and included 4-8 electrodes. Micromolded ribs were placed at the perimetry for strength and case of manipulation. The PDMS arrays were implanted epiretinally in four normal dogs, with a single retina] tack used in each case to hold the device on the retina. The mechanical effects of the implant were followed up after surgical implantation by photography, fluorescein angiography, optical coherence tomography (OCT), and electrophysiologic tests. An intraoperative retinal tear occurred in the first implanted dog, causing retinal detachment and necessitating termination. The remaining dogs experienced no gross complications secondary to the array implantation procedure. During the follow-up period of 2 months in one eye and 6 months in three eyes, OCT demonstrated that the arrays were in close contact with the retina. Fluorescein angiography showed good perfusion of the retina under the array. At the end of 6 months, there was no statistical difference from baseline in mean retinal thickness under the array (P=0.43) or peripapillary retinal nerve fibre layer thickness corresponding to the implanted area (P=0.34). The mean distance between the array and the retinal surface varied from 32 to 68 pm throughout the follow-up. Histopathologic evaluation of the retinal implantation site in eyes followed for 6 months showed a general preservation of the normal, layered retinal structure, except for some localized retinal thinning in two eyes, where the array frame had been in direct retinal contact. The PDMS substrate micro array is a new and promising technology that can be scaled to support a high-density retinal stimulating array. Its implantation and handling is surgically manageable, and it forms a mechanically stable, acceptable interface with the inner retinal surface. (C) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:81 / 90
页数:10
相关论文
共 15 条
[1]   Optical coherence tomography assessment of retinal nerve fiber laver thickness changes after glaucoma surgery [J].
Aydin, A ;
Wollstein, G ;
Price, LL ;
Fujimoto, JG ;
Schuman, JS .
OPHTHALMOLOGY, 2003, 110 (08) :1506-1511
[2]   Quantitative assessment of structural damage in eyes with localized visual field abnormalities [J].
Bagga, H ;
Greenfield, DS .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (05) :797-805
[3]   Visually guided performance of simple tasks using simulated prosthetic vision [J].
Hayes, JS ;
Yin, VT ;
Piyathaisere, D ;
Weiland, JD ;
Humayun, MS ;
Dagnelie, G .
ARTIFICIAL ORGANS, 2003, 27 (11) :1016-1028
[4]   Pattern electrical stimulation of the human retina [J].
Humayun, MS ;
de Juan, E ;
Weiland, JD ;
Dagnelie, G ;
Katona, S ;
Greenberg, R ;
Suzuki, S .
VISION RESEARCH, 1999, 39 (15) :2569-2576
[5]   Visual perception elicited by electrical stimulation of retina in blind humans [J].
Humayun, MS ;
deJuan, E ;
Dagnelie, G ;
Greenberg, RJ ;
Prost, RH ;
Phillips, DH .
ARCHIVES OF OPHTHALMOLOGY, 1996, 114 (01) :40-46
[6]   Visual perception in a blind subject with a chronic microelectronic retinal prosthesis [J].
Humayun, MS ;
Weiland, JD ;
Fujii, GY ;
Greenberg, R ;
Williamson, R ;
Little, J ;
Mech, B ;
Cimmarusti, V ;
Van Boemel, G ;
Dagnelie, G ;
de Juan, E .
VISION RESEARCH, 2003, 43 (24) :2573-2581
[7]   Synthesis, permeability and biocompatibility of tricomponent membranes containing polyethylene glycol, polydimethylsiloxane and polypentamethylcyclopentasiloxane domains [J].
Kurian, P ;
Kasibhatla, B ;
Daum, J ;
Burns, CA ;
Moosa, M ;
Rosenthal, KS ;
Kennedy, JP .
BIOMATERIALS, 2003, 24 (20) :3493-3503
[8]  
Majji AB, 1999, INVEST OPHTH VIS SCI, V40, P2073
[9]   Polydimethylsiloxane/polyether-mixed macrodiol-based polyurethane elastomers: biostability [J].
Martin, DJ ;
Warren, LAP ;
Gunatillake, PA ;
McCarthy, SJ ;
Meijs, GF ;
Schindhelm, K .
BIOMATERIALS, 2000, 21 (10) :1021-1029
[10]   Identifying early glaucoma with optical coherence tomography [J].
Nouri-Mahdavi, K ;
Hoffman, D ;
Tannenbaum, DP ;
Law, SK ;
Caprioli, J .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (02) :228-235