Adsorption of proteins on electro-conductive polymer films

被引:30
作者
Khan, GF [1 ]
Wernet, W [1 ]
机构
[1] CIBA GEIGY JAPAN LTD,INT RES LABS,NEW MAT RES DEPT,TAKARAZUKA,HYOGO 665,JAPAN
关键词
adsorption; biomaterials; conductivity; polymers;
D O I
10.1016/S0040-6090(96)09518-1
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Shapable electro-conductive (SEC) polymer films (polyanion-doped polypyrrole films) show several interesting properties for bioelectrochemical applications. The SEC film can be used as an inert, stable and hydrophobic electrode in aqueous solution over a wide potential range. In this study, the physical and the potential-assisted adsorption of various proteins on the SEC film is described. Because of the hydrophobic surface characteristic proteins easily adsorb and retain on the film surface by strong hydrophobic interactions. The amount of the adsorbed protein varies from 2.2 to 4.8 mu g cm(-2) depending on the protein when the film is incubated for 22 h in the protein solution. The adsorption is effectively accelerated and enhanced by applying a positive potential in the range from 0.4 V to 1.0 V (vs. Ag/AgCl). The potential-assisted adsorption process is completed by 10-15 min and the amount of the adsorbed protein is nearly doubled as compared to the adsorption without potential. The adsorbed protein is chemically very stable in comparison with the protein in solution. More than 85% of the initial adsorbed proteins retains on the surface after three weeks of incubation in buffer solution. The initial adsorption rate is studied by quartz crystal micro-balance measurements on a thin polymer film coated quartz crystal. In addition, the SEC film surface is etched with air plasma which leads to a four-fold increase of the adsorption of proteins. (C) 1997 Elsevier Science S.A.
引用
收藏
页码:265 / 271
页数:7
相关论文
共 29 条
[1]   AMPEROMETRIC NEEDLE-TYPE GLUCOSE SENSOR BASED ON A MODIFIED PLATINUM-ELECTRODE WITH DIMINISHED RESPONSE TO INTERFERING MATERIALS [J].
CHEN, CY ;
GOTOH, M ;
MAKINO, H ;
SU, YC ;
TAMIYA, E ;
KARUBE, I .
ANALYTICA CHIMICA ACTA, 1992, 265 (01) :5-14
[2]   PROTEIN ADSORPTION ON LOW-TEMPERATURE ISOTROPIC CARBON .2. EFFECTS OF SURFACE-CHARGE OF SOLIDS [J].
FENG, L ;
ANDRADE, JD .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1994, 166 (02) :419-426
[3]   IMMOBILIZATION OF LACTATE OXIDASE IN A POLY(VINYL ALCOHOL) MATRIX ON PLATINIZED GRAPHITE-ELECTRODES BY CHEMICAL CROSS-LINKING WITH ISOCYANATE [J].
HAJIZADEH, K ;
HALSALL, HB ;
HEINEMAN, WR .
TALANTA, 1991, 38 (01) :37-47
[4]  
HUANG YL, 1993, ANAL CHIM ACTA, V283, P763
[5]   DIFFERENTIAL PULSE VOLTAMMETRIC STUDY OF DIRECT ELECTRON-TRANSFER IN GLUCOSE-OXIDASE CHEMICALLY MODIFIED GRAPHITE-ELECTRODES [J].
IANNIELLO, RM ;
LINDSAY, TJ ;
YACYNYCH, AM .
ANALYTICAL CHEMISTRY, 1982, 54 (07) :1098-1101
[6]   ELECTROCATALYSIS WITH A GLUCOSE OXIDASE-IMMOBILIZED GRAPHITE ELECTRODE [J].
IKEDA, T ;
KATASHO, I ;
KAMEI, M ;
SENDA, M .
AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1984, 48 (08) :1969-1976
[7]   ELECTROCHEMICAL-BEHAVIOR OF MONOLAYER QUINOPROTEIN ADSORBED ON THE ELECTRODE SURFACE [J].
KHAN, GF ;
SHINOHARA, H ;
IKARIYAMA, Y ;
AIZAWA, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 315 (1-2) :263-273
[8]   Design of a stable charge transfer complex electrode for a third-generation amperometric glucose sensor [J].
Khan, GF ;
Ohwa, M ;
Wernet, W .
ANALYTICAL CHEMISTRY, 1996, 68 (17) :2939-2945
[9]   Platinization of shapable electroconductive polymer film for an improved glucose sensor [J].
Khan, GF ;
Wernet, W .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1996, 143 (10) :3336-3342
[10]   A SIMPLE-MODEL FOR THE ETCHING OF PHOTORESIST WITH PLASMA-GENERATED REACTANTS [J].
KORETSKY, MD ;
REIMER, JA .
JOURNAL OF APPLIED PHYSICS, 1992, 72 (11) :5081-5088