Response characteristics of thermoluminescence and alanine-based dosemeters to 16 and 25 MeV proton beams

被引:12
作者
Bartolotta, A
Tonghi, LB
Brai, M
Cuttone, G
Fattibene, P
Onori, S
Raffaele, L
Rovelli, A
Sabini, MG
Teri, G
机构
[1] Univ Palermo, Ist Farmacochim, I-90123 Palermo, Italy
[2] Ist Nazl Fis Nucl, Lab Nazl Sud, I-95123 Catania, Italy
[3] Univ Palermo, Ist Biocomunicaz, I-90127 Palermo, Italy
[4] Univ Palermo, Unita INFM, I-90127 Palermo, Italy
[5] Ist Super Sanita, Fis Lab, I-00161 Rome, Italy
[6] Ist Sci Tumori Genova, Sez Messina, I-98125 Messina, Italy
关键词
D O I
10.1093/oxfordjournals.rpd.a032870
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The proton response of LiF:Mg,Ti (TLD-100) and alanine dosemeters (prepared at the Istituto Superiore di Sanita, Rome, Italy) was studied. The irradiations were performed with proton beams with initial energies of 26.6 MeV and 18 MeV at various depths in a PMMA phantom. Results were compared with reference dosimetry provided by a Markus parallel-plate ionisation chamber and with TRIM range-effect calculations. A significant energy dependence of response was observed. The effectiveness relative to Co-60 of both dosemeters was evaluated.
引用
收藏
页码:353 / 356
页数:4
相关论文
共 8 条
[1]   THE CALIBRATION AND USE OF PLANE-PARALLEL IONIZATION CHAMBERS FOR DOSIMETRY OF ELECTRON-BEAMS - AN EXTENSION OF THE 1983 AAPM PROTOCOL REPORT OF AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO-39 [J].
ALMOND, PR ;
ATTIX, FH ;
HUMPHRIES, LJ ;
KUBO, H ;
NATH, R ;
GOETSCH, S ;
ROGERS, DWO .
MEDICAL PHYSICS, 1994, 21 (08) :1251-1260
[2]  
[Anonymous], 1993, 49 ICRU
[3]   DOSIMETRY FOR CO-60 GAMMA-RAYS WITH ALANINE [J].
BARTOLOTTA, A ;
INDOVINA, PL ;
ONORI, S ;
ROSATI, A .
RADIATION PROTECTION DOSIMETRY, 1984, 9 (04) :277-281
[4]   Preliminary assessment of LiF and alanine detectors for the dosimetry of proton therapy beams [J].
Fattibene, P ;
Calicchia, A ;
dErrico, F ;
DeAngelis, C ;
Egger, E ;
Onori, S .
RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) :305-309
[5]  
*IAEA, 1997, TECHN REP SER N, V381
[6]   IONIZATION-CHAMBER DOSIMETRY OF PROTON-BEAMS USING CYLINDRICAL AND PLANE-PARALLEL CHAMBERS - N-W VERSUS N-K ION-CHAMBER CALIBRATIONS [J].
MEDIN, J ;
ANDREO, P ;
GRUSELL, E ;
MATTSSON, O ;
MONTELIUS, A ;
ROOS, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (07) :1161-1176
[7]   Alanine dosimetry of proton therapy beams [J].
Onori, S ;
dErrico, F ;
DeAngelis, C ;
Egger, E ;
Fattibene, P ;
Janovsky, I .
MEDICAL PHYSICS, 1997, 24 (03) :447-453
[8]  
ZIEGLER JF, 1994, IBM RES, V28