Alanine dosimetry of proton therapy beams

被引:38
作者
Onori, S
dErrico, F
DeAngelis, C
Egger, E
Fattibene, P
Janovsky, I
机构
[1] IST NAZL FIS NUCL, I-00161 ROME, ITALY
[2] YALE UNIV, SCH MED, NEW HAVEN, CT USA
[3] PAUL SCHERRER INST, DIV RADIAT MED, VILLIGEN, SWITZERLAND
[4] INST NUCL RES, PRAGUE, CZECH REPUBLIC
关键词
proton therapy; alanine dosimetry;
D O I
10.1118/1.597911
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An analysis of some of the properties of the ESR-alanine dosimetry in therapeutic proton beams is reported. Thin alanine-based detectors (1 and 2 mm thick pellets and 0.25 mm thick films) were tested in a clinical 62 MeV proton beam. The response of the alanine detectors in unmodulated and modulated proton beams was studied in tissue equivalent phantoms. The dose assessed by alanine was compared to the dose provided by a Markus parallel plate ionization chamber, used for reference dosimetry. Experiments in the 5-250 Gy dose range showed linearity of alanine dose response and no significant differences in the alanine response per unit dose to gammas and protons. Agreement within the experimental uncertainties was found between the alanine and the Markus chamber depth dose curves, including the Bragg peak region. (C) 1997 American Association of Physicists in Medicine.
引用
收藏
页码:447 / 453
页数:7
相关论文
共 23 条
[1]  
[Anonymous], 1995, ANN BOOK ASTM STAND, DOI DOI 10.1520/2002C
[2]   FADING CHARACTERISTICS OF IRRADIATED ALANINE PELLETS - THE IMPORTANCE OF PREIRRADATION CONDITIONING [J].
ARBER, JM ;
SHARPE, PHG .
APPLIED RADIATION AND ISOTOPES, 1993, 44 (1-2) :19-22
[3]  
BARTOLOTTA A, 1990, RADIAT PHYS CHEM, V35, P708
[4]   DOSIMETRY FOR CO-60 GAMMA-RAYS WITH ALANINE [J].
BARTOLOTTA, A ;
INDOVINA, PL ;
ONORI, S ;
ROSATI, A .
RADIATION PROTECTION DOSIMETRY, 1984, 9 (04) :277-281
[5]   SOURCES OF UNCERTAINTY IN THERAPY LEVEL ALANINE DOSIMETRY [J].
BARTOLOTTA, A ;
FATTIBENE, P ;
ONORI, S ;
PANTALONI, M ;
PETETTI, E .
APPLIED RADIATION AND ISOTOPES, 1993, 44 (1-2) :13-17
[6]   THE EFFECTS OF DOSE AND RADIATION QUALITY ON THE SHAPE AND POWER SATURATION OF THE EPR SIGNAL IN ALANINE [J].
CIESIELSKI, B ;
WIELOPOLSKI, L .
RADIATION RESEARCH, 1994, 140 (01) :105-111
[7]   INFLUENCE OF THICK INHOMOGENEITIES ON CHARGED-PARTICLE BEAMS [J].
GOITEIN, M ;
SISTERSON, JM .
RADIATION RESEARCH, 1978, 74 (02) :217-230
[8]  
HANSEN JW, 1989, APPL RADIAT ISOTOPES, V40, P935, DOI 10.1016/0883-2889(89)90019-1
[9]   THEORETICAL AND EXPERIMENTAL RADIATION EFFECTIVENESS OF THE FREE-RADICAL DOSIMETER ALANINE TO IRRADIATION WITH HEAVY CHARGED-PARTICLES [J].
HANSEN, JW ;
OLSEN, KJ .
RADIATION RESEARCH, 1985, 104 (01) :15-27
[10]  
*INT COMM RAD UN M, 1993, 49 ICRU CRU INT COMM