Iterative reconstruction techniques for computed tomography part 2: initial results in dose reduction and image quality

被引:248
作者
Willemink, Martin J. [1 ]
Leiner, Tim [1 ]
de Jong, Pim A. [1 ]
de Heer, Linda M.
Nievelstein, Rutger A. J. [1 ]
Schilham, Arnold M. R. [1 ]
Budde, Ricardo P. J. [1 ,2 ]
机构
[1] Univ Utrecht, Med Ctr, Dept Radiol, NL-3508 GA Utrecht, Netherlands
[2] Gelre Hosp, Dept Radiol, Apeldoorn, Netherlands
关键词
Iterative reconstruction; Computed tomography; Low dose; Filtered back-projection; Systematic review; FILTERED BACK-PROJECTION; CORONARY CT ANGIOGRAPHY; LOW-TUBE-VOLTAGE; CHEST CT; ALGORITHM; PERFORMANCE; NOISE; ASIR; ENTEROGRAPHY; FEASIBILITY;
D O I
10.1007/s00330-012-2764-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
To present the results of a systematic literature search aimed at determining to what extent the radiation dose can be reduced with iterative reconstruction (IR) for cardiopulmonary and body imaging with computed tomography (CT) in the clinical setting and what the effects on image quality are with IR versus filtered back-projection (FBP) and to provide recommendations for future research on IR. We searched Medline and Embase from January 2006 to January 2012 and included original research papers concerning IR for CT. The systematic search yielded 380 articles. Forty-nine relevant studies were included. These studies concerned: the chest(n = 26), abdomen(n = 16), both chest and abdomen(n = 1), head(n = 4), spine(n = 1), and no specific area (n = 1). IR reduced noise and artefacts, and it improved subjective and objective image quality compared to FBP at the same dose. Conversely, low-dose IR and normal-dose FBP showed similar noise, artefacts, and subjective and objective image quality. Reported dose reductions ranged from 23 to 76 % compared to locally used default FBP settings. However, IR has not yet been investigated for ultra-low-dose acquisitions with clinical diagnosis and accuracy as endpoints. Benefits of IR include improved subjective and objective image quality as well as radiation dose reduction while preserving image quality. Future studies need to address the value of IR in ultra-low-dose CT with clinically relevant endpoints. aEuro cent Iterative reconstruction improves image quality of CT images at equal acquisition parameters. aEuro cent IR preserves image quality compared to normal-dose filtered back-projection. aEuro cent The reduced radiation dose made possible by IR is advantageous for patients. aEuro cent IR has not yet been investigated with clinical diagnosis and accuracy as endpoints.
引用
收藏
页码:1632 / 1642
页数:11
相关论文
共 59 条
[1]
[Anonymous], ROFO
[2]
[Anonymous], AIDR 3D REDUCES DOSE
[3]
[Anonymous], IDOSE4 IT REC TECHN
[4]
[Anonymous], 16262 EUR DAN SOC RA
[5]
Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience [J].
Bittencourt, Marcio Sommer ;
Schmidt, Bernhard ;
Seltmann, Martin ;
Muschiol, Gerd ;
Ropers, Dieter ;
Daniel, Werner Guenther ;
Achenbach, Stephan .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07) :1081-1087
[6]
Reducing the radiation dose for low-dose CT of the paranasal sinuses using iterative reconstruction: Feasibility and image quality [J].
Bulla, Stefan ;
Blanke, Philipp ;
Hassepass, Frederike ;
Krauss, Tobias ;
Winterer, Jan Thorsten ;
Breunig, Christine ;
Langer, Mathias ;
Pache, Gregor .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) :2246-2250
[7]
Estimating Effective Dose for CT Using Dose-Length Product Compared With Using Organ Doses: Consequences of Adopting International Commission on Radiological Protection Publication 103 or Dual-Energy Scanning [J].
Christner, Jodie A. ;
Kofler, James M. ;
McCollough, Cynthia H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (04) :881-889
[8]
Impact of Adaptive Statistical Iterative Reconstruction (ASIR) on Radiation Dose and Image Quality in Aortic Dissection Studies: A Qualitative and Quantitative Analysis [J].
Cornfeld, Daniel ;
Israel, Gary ;
Detroy, Ezra ;
Bokhari, Jamal ;
Mojibian, Hamid .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (03) :W336-W340
[9]
Computed tomography-old ideas and new technology [J].
Fleischmann, Dominik ;
Boas, F. Edward .
EUROPEAN RADIOLOGY, 2011, 21 (03) :510-517
[10]
Reducing the Radiation Dose for CT Colonography Using Adaptive Statistical Iterative Reconstruction: A Pilot Study [J].
Flicek, Kristina T. ;
Hara, Amy K. ;
Silva, Alvin C. ;
Wu, Qing ;
Peter, Mary B. ;
Johnson, C. Daniel .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (01) :126-131