Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience

被引:116
作者
Bittencourt, Marcio Sommer [1 ]
Schmidt, Bernhard [2 ]
Seltmann, Martin [3 ]
Muschiol, Gerd [3 ]
Ropers, Dieter [3 ]
Daniel, Werner Guenther [3 ]
Achenbach, Stephan [3 ]
机构
[1] Univ Sao Paulo, Sch Med, Univ Hosp, Div Internal Med, BR-05508000 Sao Paulo, Brazil
[2] Siemens Healthcare Sect, Forchheim, Germany
[3] Univ Erlangen Nurnberg, Dept Internal Med 2, D-91054 Erlangen, Germany
关键词
Coronary computed tomography; Iterative reconstruction; Image quality; CT ANGIOGRAPHY; QUALITY; RESOLUTION;
D O I
10.1007/s10554-010-9756-3
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Improvements in image quality in cardiac computed tomography may be achieved through iterative image reconstruction techniques. We evaluated the ability of "Iterative Reconstruction in Image Space" (IRIS) reconstruction to reduce image noise and improve subjective image quality. 55 consecutive patients undergoing coronary CT angiography to rule out coronary artery stenosis were included. A dual source CT system and standard protocols were used. Images were reconstructed using standard filtered back projection and IRIS. Image noise, attenuation within the coronary arteries, contrast, signal to noise and contrast to noise parameters as well as subjective classification of image quality (using a scale with four categories) were evaluated and compared between the two image reconstruction protocols. Subjective image quality (2.8 +/- 0.4 in filtered back projection and 2.8 +/- 0.4 in iterative reconstruction) and the number of "evaluable" segments per patient 14.0 +/- 1.2 in filtered back projection and 14.1 +/- 1.1 in iterative reconstruction) were not significant different between the two methods. However iterative reconstruction had a lower image noise (22.6 +/- 4.5 HU vs. 28.6 +/- 5.1 HU) and higher signal to noise and image to noise ratios in the proximal coronary arteries. IRIS reduces image noise and contrast-to-noise ratio in coronary CT angiography, thus providing potential for reducing radiation exposure.
引用
收藏
页码:1081 / 1087
页数:7
相关论文
共 17 条
[1]
Comparison of image quality in contrast-enhanced coronary artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography [J].
Achenbach, S ;
Giesler, T ;
Ropers, D ;
Ulzheimer, S ;
Anders, K ;
Wenkel, E ;
Pohle, K ;
Kachelriess, M ;
Derlien, H ;
Kalender, WA ;
Daniel, WG ;
Bautz, W ;
Baum, U .
INVESTIGATIVE RADIOLOGY, 2003, 38 (02) :119-128
[2]
Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition [J].
Achenbach, Stephan ;
Marwan, Mohamed ;
Ropers, Dieter ;
Schepis, Tiziano ;
Pflederer, Tobias ;
Anders, Katharina ;
Kuettner, Axel ;
Daniel, Werner G. ;
Uder, Michael ;
Lell, Michael M. .
EUROPEAN HEART JOURNAL, 2010, 31 (03) :340-346
[3]
Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[4]
Radiation Dose and Safety in Cardiac Computed Tomography [J].
Gerber, Thomas C. ;
Kantor, Birgit ;
McCollough, Cynthia H. .
CARDIOLOGY CLINICS, 2009, 27 (04) :665-+
[5]
Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study [J].
Hara, Amy K. ;
Paden, Robert G. ;
Silva, Alvin C. ;
Kujak, Jennifer L. ;
Lawder, Holly J. ;
Pavlicek, William .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) :764-771
[6]
Estimated Radiation Dose Associated With Cardiac CT Angiography [J].
Hausleiter, Joerg ;
Meyer, Tanja ;
Hermann, Franziska ;
Hadamitzky, Martin ;
Krebs, Markus ;
Gerber, Thomas C. ;
McCollough, Cynthia ;
Martinoff, Stefan ;
Kastrati, Adnan ;
Schoemig, Albert ;
Achenbach, Stephan .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 301 (05) :500-507
[7]
IMV Medical Information Division, 2007, CT MARK SUMM REP
[8]
Strategies for CT radiation dose optimization [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Hamberg, LM ;
Blake, MA ;
Shephard, JA ;
Saini, S .
RADIOLOGY, 2004, 230 (03) :619-628
[9]
A new iterative reconstruction technique for attenuation correction in high-resolution positron emission tomography [J].
Knesaurek, K ;
Machac, J ;
Vallabhajosula, S ;
Buchsbaum, MS .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (06) :656-661
[10]
Adaptive Statistical Iterative Reconstruction: Assessment of Image Noise and Image Quality in Coronary CT Angiography [J].
Leipsic, Jonathon ;
LaBounty, Troy M. ;
Heilbron, Brett ;
Min, James K. ;
Mancini, G. B. John ;
Lin, Fay Y. ;
Taylor, Carolyn ;
Dunning, Allison ;
Earls, James P. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) :649-654