Estimated Radiation Dose Associated With Cardiac CT Angiography

被引:773
作者
Hausleiter, Joerg [1 ]
Meyer, Tanja [1 ]
Hermann, Franziska [1 ]
Hadamitzky, Martin [1 ]
Krebs, Markus [1 ]
Gerber, Thomas C. [3 ]
McCollough, Cynthia [4 ]
Martinoff, Stefan [2 ]
Kastrati, Adnan [1 ]
Schoemig, Albert [1 ]
Achenbach, Stephan [5 ]
机构
[1] Tech Univ Munich, Dept Cardiol, Deutsch Herzzentrum Munchen, Klin Tech, D-80636 Munich, Germany
[2] Tech Univ Munich, Dept Radiol & Nucl Med, Deutsch Herzzentrum Munchen, Klin Tech, D-80636 Munich, Germany
[3] Mayo Clin, Dept Cardiovasc Dis, Jacksonville, FL 32224 USA
[4] Mayo Clin, Dept Radiol, Rochester, MN USA
[5] Univ Klinikum Erlangen, Dept Cardiol, Med Klin 2, Erlangen, Germany
来源
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION | 2009年 / 301卷 / 05期
关键词
TOMOGRAPHY CORONARY-ANGIOGRAPHY; MULTISLICE COMPUTED-TOMOGRAPHY; RADIOLOGY; COMMITTEE; EXPOSURE; QUALITY; HEART; RISK;
D O I
10.1001/jama.2009.54
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Context Cardiac computed tomography ( CT) angiography ( CCTA) has emerged as a useful diagnostic imaging modality in the assessment of coronary artery disease. However, the potential risks due to exposure to ionizing radiation associated with CCTA have raised concerns. Objectives To estimate the radiation dose of CCTA in routine clinical practice as well as the association of currently available strategies with dose reduction and to identify the independent factors contributing to radiation dose. Design, Setting, and Patients A cross- sectional, international, multicenter, observational study ( 50 study sites: 21 university hospitals and 29 community hospitals) of estimated radiation dose in 1965 patients undergoing CCTA between February and December 2007. Linear regression analysis was used to identify independent predictors associated with dose. Main Outcome Measure Dose- length product ( DLP) of CCTA. Results The median DLP of 1965 CCTA examinations performed at 50 study sites was 885 mGy x cm ( interquartile range, 568- 1259 mGy x cm), which corresponds to an estimated radiation dose of 12 mSv ( or 1.2 x the dose of an abdominal CT study or 600 chest x- rays). A high variability in DLP was observed between study sites ( range of median DLPs per site, 331- 2146 mGy x cm). Independent factors associated with radiation dose were patient weight ( relative effect on DLP, 5%; 95% confidence interval [ CI], 4%- 6%), absence of stable sinus rhythm ( 10%; 95% CI, 2%- 19%), scan length ( 5%; 95% CI, 4%- 6%), electrocardiographically controlled tube current modulation (- 25%; 95% CI, - 23% to - 28%; applied in 73% of patients), 100- kV tube voltage (- 46%; 95% CI, - 42% to - 51%; applied in 5% of patients), sequential scanning (- 78%; 95% CI, - 77% to - 79%; applied in 6% of patients), experience in cardiac CT (- 1%; 95% CI, - 1% to 0%), number of CCTAs per month ( 0%; 95% CI, 0%- 1%), and type of 64- slice CT system ( for highest vs lowest dose system, 97%; 95% CI, 88%- 106%). Algorithms for dose reduction were not associated with deteriorated diagnostic image quality in this observational study. Conclusions Median doses of CCTA differ significantly between study sites and CT systems. Effective strategies to reduce radiation dose are available but some strategies are not frequently used. The comparable diagnostic image quality may support an increased use of dose- saving strategies in adequately selected patients.
引用
收藏
页码:500 / 507
页数:8
相关论文
共 24 条
[1]  
[Anonymous], 2004, EUROPEAN GUIDELINES
[2]  
[Anonymous], 2007, R LANG ENV STAT COMP
[3]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[4]   Assessment of coronary artery disease by cardiac computed tomography - A scientific statement from the American Heart Association committee on cardiovascular imaging and intervention, council on cardiovascular radiology and intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology [J].
Budoff, Matthew J. ;
Achenbach, Stephan ;
Blumenthal, Roger S. ;
Carr, J. Jeffrey ;
Goldin, Jonathan G. ;
Greenland, Philip ;
Guerci, Alan D. ;
Lima, Joao A. C. ;
Rader, Daniel J. ;
Rubin, Geoffrey D. ;
Shaw, Leslee J. ;
Wiegers, Susan E. .
CIRCULATION, 2006, 114 (16) :1761-1791
[5]   Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography [J].
Coles, DR ;
Smail, MA ;
Negus, IS ;
Wilde, P ;
Oberhoff, M ;
Karsch, KR ;
Baumbach, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (09) :1840-1845
[6]  
Di Carli MF, 2006, J NUCL MED, V47, P1397
[7]  
Diggle P.J., 1993, ANAL LONGITUDINAL DA
[8]   Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose [J].
Earls, James P. ;
Berman, Elise L. ;
Urban, Bruce A. ;
Curry, Charlene A. ;
Lane, Judith L. ;
Jennings, Robert S. ;
McCulloch, Colin C. ;
Hsieh, Jiang ;
Londt, John H. .
RADIOLOGY, 2008, 246 (03) :742-753
[9]   Radiation dose to patients from cardiac diagnostic imaging [J].
Einstein, Andrew J. ;
Moser, Kevin W. ;
Thompson, Randall C. ;
Cerqueira, Manuel D. ;
Henzlova, Milena J. .
CIRCULATION, 2007, 116 (11) :1290-1305
[10]   Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography [J].
Einstein, Andrew J. ;
Henzlova, Milena J. ;
Rajagopalan, Sanjay .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (03) :317-323