Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition

被引:452
作者
Achenbach, Stephan [1 ]
Marwan, Mohamed [1 ]
Ropers, Dieter [1 ]
Schepis, Tiziano [1 ]
Pflederer, Tobias [1 ]
Anders, Katharina [2 ]
Kuettner, Axel [2 ]
Daniel, Werner G. [1 ]
Uder, Michael [2 ]
Lell, Michael M. [2 ]
机构
[1] Univ Erlangen Nurnberg, Dept Cardiol, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Radiol, D-91054 Erlangen, Germany
关键词
Computed tomography; Coronary CT angiography; Dual-source CT; Radiation exposure; IMAGE QUALITY; CT ANGIOGRAPHY; RADIATION-EXPOSURE; AMERICAN-COLLEGE; GUIDELINES; MANAGEMENT; REDUCTION; COMMITTEE; ANGINA; UPDATE;
D O I
10.1093/eurheartj/ehp470
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the feasibility and image quality of a new scan mode for coronary computed tomography angiography (CTA) with an effective dose of less than 1 mSv. In 50 consecutive patients (body weight < 100 kg, sinus rhythm < 60 b.p.m. after pre-medication, coronary CTA was performed using a dual-source CT system with 2 x 128 x 0.6 mm collimation, 0.28 s rotation time, a pitch of 3.2 or 3.4, 100 kV tube voltage and current of 320 mA s. Data acquisition was prospectively triggered at 60% of the R-R interval and completed within one cardiac cycle. Image quality was evaluated using a four-point scale (1 = absence of any artefacts to 4 = uninterpretable). In all 50 patients, imaging was successful. Mean duration of data acquisition was 258 +/- 20 ms. Mean dose-length product was 62 +/- 5 mGy cm, the effective dose was 0.87 +/- 0.07 mSv (0.78-0.99 mSv). Of the 742 coronary artery segments, 94% had an image quality score of 1, 5.0% a score of 2, 0.9% a score of 3, and 4 segments (0.5%) were 'uninterpretable'. In non-obese patients with a low and stable heart rate, prospectively ECG-triggered high-pitch spiral coronary CTA provides excellent image quality at a consistent dose below 1.0 mSv.
引用
收藏
页码:340 / 346
页数:7
相关论文
共 30 条
[1]   Dual-source cardiac computed tomography: image quality and dose considerations [J].
Achenbach, Stephan ;
Anders, Katharina ;
Kalender, Willi A. .
EUROPEAN RADIOLOGY, 2008, 18 (06) :1188-1198
[2]   Influence of slice thickness and reconstruction kernel on the computed tomographic attenuation of coronary atherosclerotic plaque [J].
Achenbach, Stephan ;
Boehmer, Kerstin ;
Pflederer, Tobias ;
Ropers, Dieter ;
Seltmann, Martin ;
Lell, Michael ;
Anders, Katharina ;
Kuettner, Axel ;
Uder, Michael ;
Daniel, Werner G. ;
Marwan, Mohamed .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2010, 4 (02) :110-115
[3]  
[Anonymous], BIOMETRICS
[4]  
Bongartz G., 2004, European guidelines for multislice computed tomography
[5]   Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose [J].
Earls, James P. ;
Berman, Elise L. ;
Urban, Bruce A. ;
Curry, Charlene A. ;
Lane, Judith L. ;
Jennings, Robert S. ;
McCulloch, Colin C. ;
Hsieh, Jiang ;
Londt, John H. .
RADIOLOGY, 2008, 246 (03) :742-753
[6]   Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography [J].
Einstein, Andrew J. ;
Henzlova, Milena J. ;
Rajagopalan, Sanjay .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (03) :317-323
[7]  
ERTEL D, EUR RADIOL
[8]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[9]   2007 chronic angina focused update of the ACC/AHA 2002 guidelines for the management of patients with chronic stable angina [J].
Fraker, Theodore D. ;
Fihn, Stephan D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (23) :2264-2274
[10]   Non-invasive detection of coronary artery disease in patients with left bundle branch block using 64-slice computed tomography [J].
Ghostine, Said ;
Caussin, Christophe ;
Daoud, Beatrice ;
Habis, Michel ;
Perrier, Eric ;
Pesenti-Rossi, David ;
Sigal-Cinqualbre, Anne ;
Angel, Claude-Yves ;
Lancelin, Bernard ;
Capderou, Andre ;
Paul, Jean-Francois .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (10) :1929-1934